Flow waveform analysis and long-term results of autogenous saphenous vein and polytetrafluoroethylene grafts in 140 arterial reconstructions of the lower limbs. 1990

K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
Second Department of Surgery, Faculty of Medicine, Kyushu University, Fukuoka, Japan.

In previous work we have found that the outcome of grafts in the lower limbs correlated with the flow waveform pattern of the artery. We have retrospectively reviewed 140 femoro-popliteal bypass operations involving the use of 75 saphenous vein grafts and 65 polytetrafluoroethylene (PTFE) grafts. For grafts with type 0 or I flow waveform pattern the patency at 4 years (56%) was superior to grafts with the type II, III or IV flow waveform (35%) patterns (P less than 0.05). For saphenous vein grafts with type 0 or I flow, the patency rate was 78% at 3 years and 69% at 5 and 8 years. In contrast with type II, III or IV flow the patency rate was 52% at 3 years, 48% at 5 years and 34% at 8 years, with a statistical significance at 4 years (P less than 0.05). PTFE grafts with type 0 or I flow showed a tendency toward an increased patency which was not significant in comparison with the grafts with type II, III or IV flow (P = 0.12). Saphenous vein grafts with type II flow patterns had an increased occlusive rate in the first year whereas PTFE grafts had the same tendency within 2 years. In both types of graft, early occlusions within a month of operation were encountered in grafts with a type III or IV flow waveform pattern. These results indicate that the fate of the reconstructed arteries of the lower limb could be predicted by flow waveform analysis, and a careful and serial postoperative evaluation of the graft should be made, particularly those with type II, III or IV flow waveform patterns.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011138 Polytetrafluoroethylene Homopolymer of tetrafluoroethylene. Nonflammable, tough, inert plastic tubing or sheeting; used to line vessels, insulate, protect or lubricate apparatus; also as filter, coating for surgical implants or as prosthetic material. Synonyms: Fluoroflex; Fluoroplast; Ftoroplast; Halon; Polyfene; PTFE; Tetron. FEP,Fluon,Politef,Polytef,TFE,Teflon,Expanded PTFE,Fluoroplast,GORE-TEX,Goretex,PTFE,Tarflen,GORE TEX,PTFE, Expanded
D011150 Popliteal Artery The continuation of the femoral artery coursing through the popliteal fossa; it divides into the anterior and posterior tibial arteries. Arteria Poplitea,Artery, Popliteal,Popliteal Arteries
D012039 Regional Blood Flow The flow of BLOOD through or around an organ or region of the body. Blood Flow, Regional,Blood Flows, Regional,Flow, Regional Blood,Flows, Regional Blood,Regional Blood Flows
D001807 Blood Vessel Prosthesis Device constructed of either synthetic or biological material that is used for the repair of injured or diseased blood vessels. Vascular Prosthesis,Blood Vessel Prostheses,Tissue-Engineered Vascular Graft,Graft, Tissue-Engineered Vascular,Grafts, Tissue-Engineered Vascular,Prostheses, Blood Vessel,Prostheses, Vascular,Prosthesis, Blood Vessel,Prosthesis, Vascular,Tissue Engineered Vascular Graft,Tissue-Engineered Vascular Grafts,Vascular Graft, Tissue-Engineered,Vascular Grafts, Tissue-Engineered,Vascular Prostheses,Vessel Prostheses, Blood,Vessel Prosthesis, Blood
D005260 Female Females
D005263 Femoral Artery The main artery of the thigh, a continuation of the external iliac artery. Common Femoral Artery,Arteries, Common Femoral,Arteries, Femoral,Artery, Common Femoral,Artery, Femoral,Common Femoral Arteries,Femoral Arteries,Femoral Arteries, Common,Femoral Artery, Common
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic

Related Publications

K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
November 1981, Surgery,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
October 1979, The British journal of surgery,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
December 1969, Revista paulista de medicina,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
January 1989, The Journal of cardiovascular surgery,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
July 2001, Journal of vascular surgery,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
January 1998, Texas Heart Institute journal,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
January 2015, Annals of surgical treatment and research,
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
July 1980, Archives of surgery (Chicago, Ill. : 1960),
K Okadome, and S Mii, and T Onohara, and A Fukuda, and K Sugimachi
January 1962, Surgery,
Copied contents to your clipboard!