Binding of histamine and histamine analogs to lymphocyte subsets analyzed by flow cytometry. 1985

K Muirhead, and P Bender, and N Hanna, and G Poste

The binding of histamine, 4-methylhistamine (a histamine type 2 receptor agonist), cimetidine (a histamine type 2 receptor antagonist), and telemethylhistamine (an inactive analog) to human peripheral blood mononuclear cell subsets was investigated by flow cytometry by using conjugates of these ligands coupled to fluorescein-labeled human serum albumin. Our results indicate that binding of fluorescent protein conjugates of histamine and its analogs does not selectively identify a lymphocyte subset(s) that mediates the immunomodulatory effects of histaminergic ligands. Conjugates with both low (2.5 to 2.8:1) and high (28 to 57:1) ligand to protein coupling ratios were used. No binding above background could be detected for the low mole ratio reagents. The high mole ratio reagents were bound by 95 to 99% of all lymphocytes when used at ligand concentrations of 50 microM or greater. At lower ligand concentrations, the number of lymphocytes exceeding a set fluorescence threshold was decreased, but fluorescence distributions remained unimodal at all concentrations used (1 to 500 microM). Monocytes also bound the high mole ratio reagents and gave rise to a second high-intensity peak in the fluorescence distribution unless they were excluded by other means. Levels of conjugate binding detected by flow cytometry did not parallel ligand potencies at classical histamine type 2 receptors; at equivalent ligand concentrations, approximately equal amounts of histamine or 4-methylhistamine conjugate were bound per lymphocyte, and only 30% less telemethylhistamine conjugate was bound. Competition with free ligands (10(2)- to 10(4)-fold excess histamine, 4-methylhistamine, cimetidine, or telemethylhistamine) did not significantly decrease the level of binding observed for the high mole ratio reagents at bound ligand concentrations of 1 to 25 microM. Dual staining with fluorescein-labeled conjugate and phycoerythrin-labeled monoclonal antibodies Leu-3ab (anti-helper T), Leu-2a (anti-suppressor T), Leu-M3 (anti-monocyte), or anti-HLA-DR (B cells and monocytes) was also carried out. The extent of conjugate binding to helper and suppressor cells was identical for each of the ligands used, but higher levels of conjugate binding were seen for monocytes and B cells than for T cells in every case. Our data do not exclude the possibility of enhanced conjugate binding to small numbers of activated (HLA-DR positive) T cells that might be involved in mediation of histamine effects.(ABSTRACT TRUNCATED AT 400 WORDS)

UI MeSH Term Description Entries
D007700 Kinetics The rate dynamics in chemical or physical systems.
D008214 Lymphocytes White blood cells formed in the body's lymphoid tissue. The nucleus is round or ovoid with coarse, irregularly clumped chromatin while the cytoplasm is typically pale blue with azurophilic (if any) granules. Most lymphocytes can be classified as either T or B (with subpopulations of each), or NATURAL KILLER CELLS. Lymphoid Cells,Cell, Lymphoid,Cells, Lymphoid,Lymphocyte,Lymphoid Cell
D008761 Methylhistamines Histamine substituted in any position with one or more methyl groups. Many of these are agonists for the H1, H2, or both histamine receptors.
D003080 Cold Temperature An absence of warmth or heat or a temperature notably below an accustomed norm. Cold,Cold Temperatures,Temperature, Cold,Temperatures, Cold
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D005452 Fluoresceins A family of spiro(isobenzofuran-1(3H),9'-(9H)xanthen)-3-one derivatives. These are used as dyes, as indicators for various metals, and as fluorescent labels in immunoassays. Tetraiodofluorescein
D006632 Histamine An amine derived by enzymatic decarboxylation of HISTIDINE. It is a powerful stimulant of gastric secretion, a constrictor of bronchial smooth muscle, a vasodilator, and also a centrally acting neurotransmitter. Ceplene,Histamine Dihydrochloride,Histamine Hydrochloride,Peremin
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001665 Binding Sites The parts of a macromolecule that directly participate in its specific combination with another molecule. Combining Site,Binding Site,Combining Sites,Site, Binding,Site, Combining,Sites, Binding,Sites, Combining
D001667 Binding, Competitive The interaction of two or more substrates or ligands with the same binding site. The displacement of one by the other is used in quantitative and selective affinity measurements. Competitive Binding

Related Publications

K Muirhead, and P Bender, and N Hanna, and G Poste
January 2001, Wiadomosci lekarskie (Warsaw, Poland : 1960),
K Muirhead, and P Bender, and N Hanna, and G Poste
February 2005, Journal of immunological methods,
K Muirhead, and P Bender, and N Hanna, and G Poste
March 1995, Cytometry,
K Muirhead, and P Bender, and N Hanna, and G Poste
June 1985, The American journal of cardiology,
K Muirhead, and P Bender, and N Hanna, and G Poste
June 1994, Cytometry,
K Muirhead, and P Bender, and N Hanna, and G Poste
November 1985, Annals of surgery,
K Muirhead, and P Bender, and N Hanna, and G Poste
February 2019, La Tunisie medicale,
K Muirhead, and P Bender, and N Hanna, and G Poste
March 1985, Laboratory investigation; a journal of technical methods and pathology,
K Muirhead, and P Bender, and N Hanna, and G Poste
February 1988, Kekkaku : [Tuberculosis],
K Muirhead, and P Bender, and N Hanna, and G Poste
July 1986, Cytometry,
Copied contents to your clipboard!