Transtelephonic monitoring of 25,919 implanted pacemakers. 1986

L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse

In order to evaluate the behavior of lithium-powered cardiac pacemakers, a database of 25,919 lithium-powered pacing systems including 23,517 single and 2,402 dual chambered pacemaker generators were followed in 21,750 patients. Of this group, 11,319 were currently active in addition to 7,560 who died, as well as 2,871 patients who terminated their follow-up service prior to the end-of-life of the pacemaker system. A total of 23,517 single chambered pacemakers were followed for 719,173 months of pacing. The mean time to explant for generator malfunctions was 42 months and for all pacing system malfunctions it was 38 months compared to 31.9 months and 28.6 months, respectively, for the 2,402 dual chambered units that were observed for 38,718 months. In the single chambered units, the most frequent reason for explant was battery exhaustion (37% of explants) followed by lead problems (26%) compared to 49% and 12%, respectively, for the dual chambered units. The incidence rates, defined as a transtelephonic test result, required physician decision for action or clarification of the pacing mode or program parameters and showed a high incidence rate immediately post-implant; thereafter, there was a relatively trouble-free period until the 36th month when capture, sensing, and battery problems began to occur at a steady rate reaching 4% at the end of 48 months. Similarly, for dual chambered units, an 8% incidence rate was seen within the first 3 months, followed by a quiescent period until the 28th month when the incidence rate jumped to 16%.(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D007256 Information Systems Integrated set of files, procedures, and equipment for the storage, manipulation, and retrieval of information. Ancillary Information Systems,Emergency Care Information Systems,Information Retrieval Systems,Perinatal Information System,Ancillary Information System,Information Retrieval System,Information System,Information System, Ancillary,Information System, Perinatal,Perinatal Information Systems,Systems, Information Retrieval
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013689 Telephone An instrument for reproducing sounds especially articulate speech at a distance. (Webster, 3rd ed) Switchboard Service,Service, Switchboard,Services, Switchboard,Switchboard Services,Telephones
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
November 2009, Journal of the American College of Cardiology,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
January 1987, Lancet (London, England),
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
January 1988, Srpski arhiv za celokupno lekarstvo,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
November 1988, Pacing and clinical electrophysiology : PACE,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
January 1984, Indian heart journal,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
October 1995, Pacing and clinical electrophysiology : PACE,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
April 1979, Vnitrni lekarstvi,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
January 1994, Journal of health care benefits,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
April 2015, Pacing and clinical electrophysiology : PACE,
L S Dreifus, and A Zinberg, and P Hurzeler, and A D Puziak, and R Pennock, and M Feldman, and D P Morse
May 1991, Hospital practice (Office ed.),
Copied contents to your clipboard!