Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth. 2014

Haya Matuoq Al Farhan
Department of Optometry and Vision Sciences, College of Applied Medicine Sciences, King Saud University, P,O, Box 10219, Riyadh 11433, Kingdom of Saudi Arabia. halfarhan@ksu.edu.sa.

BACKGROUND The aim was to compare the anterior chamber depth (ACD) measurements taken with Orbscan II, ultrasound biomicroscopy (UBM) and the Artemis-2 VHF (very-high-frequency) ultrasound scanner in normal subjects. METHODS In this prospective study, one eye from each of 60 normal subjects was randomly selected. Three subjects dropped out of the study because they were apprehensive about the UBM examination; their data were excluded entirely. Measurements of ACD were taken with the Orbscan II, UBM and Artemis-2 VHFUS. Results were obtained for coefficient of variance (CV) and intra-class correlation coefficient (ICC), and statistical analysis was by repeated-measures analysis of variance (ANOVA) for intra-observer repeatability. ANOVA and Bland-Altman analyses were used to determine limits of agreement (LOA) between the three instruments. RESULTS The average ACD (± standard deviation) was 3.13 ± 0.34 mm, 2.96 ± 0.27 mm and 2.87 ± 0.31 mm for the Orbscan II, UBM and Artemis-2 VHFUS, respectively. The repeatability scores were 0.015 ± 0.014%, 0.08 ± 0.09% and 0.07 ± 0.06% for the Orbscan II, UBM and Artemis-2 VHFUS, respectively. The ICC for repeatability of Orbscan II, UBM and Artemis-2 VHFUS measurements was high and equal to 0.99%. The intra-observer repeatability scores of the ACD measurement p-values using Orbscan II, UBM and Artemis-2 VHFUS were 0.12, 0.70 and 0.10, respectively. The mean difference and standard deviations for ACD measurements using Orbscan II vs UBM, Orbscan II vs Artemis-2 VHFUS and UBM vs Artemis-2 VHFUS were 0.17 ± 0.31 mm, 0.27 ± 0.34 mm and 0.10 ± 0.18 mm, respectively. LOAs were 0.78 to -0.44 mm, 0.93 to -0.39 mm and 0.45 to -0.26 mm. ANOVA revealed a statistically significant difference between the Orbscan II, UBM and Artemis-2 VHFUS (p < 0.0001). CONCLUSIONS Measurements by the three instruments show high repeatability. UBM and the Artemis-2 VHFUS can be used interchangeably, but the Orbscan II cannot be used interchangeably with UBM or the Artemis-2 VHFUS.

UI MeSH Term Description Entries
D008297 Male Males
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D003941 Diagnostic Techniques, Ophthalmological Methods and procedures for the diagnosis of diseases of the eye or of vision disorders. Diagnostic Technic, Ophthalmological,Diagnostic Technics, Ophthalmologic,Diagnostic Technics, Ophthalmological,Diagnostic Technique, Ophthalmological,Diagnostic Techniques, Ophthalmologic,Ophthalmological Diagnostic Technic,Ophthalmological Diagnostic Technics,Ophthalmological Diagnostic Technique,Ophthalmological Diagnostic Techniques,Technic, Ophthalmological Diagnostic,Technics, Ophthalmological Diagnostic,Technique, Ophthalmological Diagnostic,Techniques, Ophthalmological Diagnostic,Diagnostic Technic, Ophthalmologic,Diagnostic Technique, Ophthalmologic,Ophthalmologic Diagnostic Technic,Ophthalmologic Diagnostic Technics,Ophthalmologic Diagnostic Technique,Ophthalmologic Diagnostic Techniques,Technic, Ophthalmologic Diagnostic,Technics, Ophthalmologic Diagnostic,Technique, Ophthalmologic Diagnostic,Techniques, Ophthalmologic Diagnostic
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000704 Analysis of Variance A statistical technique that isolates and assesses the contributions of categorical independent variables to variation in the mean of a continuous dependent variable. ANOVA,Analysis, Variance,Variance Analysis,Analyses, Variance,Variance Analyses
D000867 Anterior Chamber The space in the eye, filled with aqueous humor, bounded anteriorly by the cornea and a small portion of the sclera and posteriorly by a small portion of the ciliary body, the iris, and that part of the crystalline lens which presents through the pupil. (Cline et al., Dictionary of Visual Science, 4th ed, p109) Anterior Chambers,Chamber, Anterior,Chambers, Anterior
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015588 Observer Variation The failure by the observer to measure or identify a phenomenon accurately, which results in an error. Sources for this may be due to the observer's missing an abnormality, or to faulty technique resulting in incorrect test measurement, or to misinterpretation of the data. Two varieties are inter-observer variation (the amount observers vary from one another when reporting on the same material) and intra-observer variation (the amount one observer varies between observations when reporting more than once on the same material). Bias, Observer,Interobserver Variation,Intraobserver Variation,Observer Bias,Inter-Observer Variability,Inter-Observer Variation,Interobserver Variability,Intra-Observer Variability,Intra-Observer Variation,Intraobserver Variability,Inter Observer Variability,Inter Observer Variation,Inter-Observer Variabilities,Inter-Observer Variations,Interobserver Variabilities,Interobserver Variations,Intra Observer Variability,Intra Observer Variation,Intra-Observer Variabilities,Intra-Observer Variations,Intraobserver Variabilities,Intraobserver Variations,Observer Variations,Variabilities, Inter-Observer,Variabilities, Interobserver,Variabilities, Intra-Observer,Variabilities, Intraobserver,Variability, Inter-Observer,Variability, Interobserver,Variability, Intra-Observer,Variability, Intraobserver,Variation, Inter-Observer,Variation, Interobserver,Variation, Intra-Observer,Variation, Intraobserver,Variation, Observer,Variations, Inter-Observer,Variations, Interobserver,Variations, Intra-Observer,Variations, Intraobserver,Variations, Observer
D055815 Young Adult A person between 19 and 24 years of age. Adult, Young,Adults, Young,Young Adults

Related Publications

Haya Matuoq Al Farhan
May 2007, Journal of refractive surgery (Thorofare, N.J. : 1995),
Haya Matuoq Al Farhan
October 2005, Optometry and vision science : official publication of the American Academy of Optometry,
Haya Matuoq Al Farhan
January 2007, European journal of ophthalmology,
Haya Matuoq Al Farhan
February 2013, Journal of refractive surgery (Thorofare, N.J. : 1995),
Haya Matuoq Al Farhan
September 2010, Journal of refractive surgery (Thorofare, N.J. : 1995),
Haya Matuoq Al Farhan
June 2004, Journal of cataract and refractive surgery,
Haya Matuoq Al Farhan
November 1997, Journal of cataract and refractive surgery,
Haya Matuoq Al Farhan
January 2010, Optometry (St. Louis, Mo.),
Haya Matuoq Al Farhan
October 2005, Journal of the Medical Association of Thailand = Chotmaihet thangphaet,
Copied contents to your clipboard!