Patient dose map indications on interventional X-ray systems and validation with Gafchromic XR-RV3 film. 2015

C Bordier, and R Klausz, and L Desponds
Detection and Guidance Solutions, Image Quality and Dose Center of Excellence, GE Healthcare, 283 rue de la Minière, Buc 78530, France clemence.bordier@ge.com.

To help avoiding secondary effects of interventional procedures like skin damage, a dose map method has been developed to provide an indication of the local dose on a surface representative of individual patient shapes. To minimise user interactions, patient envelope shapes are automatically determined depending on simple patient data information. Local doses are calculated in 1-cm² areas depending on the estimated air kerma, table and gantry positions and system settings, taking into account the table and mattress attenuations and estimated backscatter from the patient. These local doses are cumulated for each location of the patient envelope during the clinical procedure. To assess the accuracy of the method, Gafchromic XR-RV3 films have been used in several operating configurations. Good visual agreements on cumulated dose localisation were obtained within the 1-cm² precision of the map and the dose values agreed within 24.9 % accuracy. The resulting dose map method has been integrated into GE Healthcare X-Ray angiographic systems and should help in the management of the dose by the users during the procedure.

UI MeSH Term Description Entries
D008954 Models, Biological Theoretical representations that simulate the behavior or activity of biological processes or diseases. For disease models in living animals, DISEASE MODELS, ANIMAL is available. Biological models include the use of mathematical equations, computers, and other electronic equipment. Biological Model,Biological Models,Model, Biological,Models, Biologic,Biologic Model,Biologic Models,Model, Biologic
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D001822 Body Burden The total amount of a chemical, metal or radioactive substance present at any time after absorption in the body of man or animal. Body Burdens,Burden, Body,Burdens, Body
D003198 Computer Simulation Computer-based representation of physical systems and phenomena such as chemical processes. Computational Modeling,Computational Modelling,Computer Models,In silico Modeling,In silico Models,In silico Simulation,Models, Computer,Computerized Models,Computer Model,Computer Simulations,Computerized Model,In silico Model,Model, Computer,Model, Computerized,Model, In silico,Modeling, Computational,Modeling, In silico,Modelling, Computational,Simulation, Computer,Simulation, In silico,Simulations, Computer
D004781 Environmental Exposure The exposure to potentially harmful chemical, physical, or biological agents in the environment or to environmental factors that may include ionizing radiation, pathogenic organisms, or toxic chemicals. Exposure, Environmental,Environmental Exposures,Exposures, Environmental
D005373 Film Dosimetry Use of a device (film badge) for measuring exposure of individuals to radiation. It is usually made of metal, plastic, or paper and loaded with one or more pieces of x-ray film. Film Badge Dosimetry,Film Badge,Badge Dosimetries, Film,Badge Dosimetry, Film,Badge, Film,Badges, Film,Dosimetries, Film,Dosimetries, Film Badge,Dosimetry, Film,Dosimetry, Film Badge,Film Badge Dosimetries,Film Badges,Film Dosimetries
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D014915 Whole-Body Counting Measurement of radioactivity in the entire human body. Whole Body Counter,Whole-Body Counters,Body Counter, Whole,Body Counters, Whole,Counter, Whole Body,Counter, Whole-Body,Counters, Whole Body,Counters, Whole-Body,Counting, Whole-Body,Whole Body Counters,Whole Body Counting,Whole-Body Counter
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations

Related Publications

C Bordier, and R Klausz, and L Desponds
September 2015, Journal of applied clinical medical physics,
C Bordier, and R Klausz, and L Desponds
June 2006, Physics in medicine and biology,
C Bordier, and R Klausz, and L Desponds
October 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB),
C Bordier, and R Klausz, and L Desponds
January 2005, Journal of applied clinical medical physics,
C Bordier, and R Klausz, and L Desponds
July 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
C Bordier, and R Klausz, and L Desponds
September 2010, Journal of radiological protection : official journal of the Society for Radiological Protection,
C Bordier, and R Klausz, and L Desponds
April 2017, Radiation protection dosimetry,
C Bordier, and R Klausz, and L Desponds
August 2005, Physics in medicine and biology,
Copied contents to your clipboard!