Continuous measurement of shear-induced platelet aggregation. 1989

M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
Department of Chemical Engineering, Waseda University, Tokyo, Japan.

A mechanical device for continuous recording of shear-induced platelet aggregation (SIPA) has been developed using a turbidometric technique. The device consists of three components: light source, a thermostated cone-plate streaming chamber and optical detection unit. There was a good correlation between platelet count and transmitted light intensity under the conditions in which no activation of platelets occurred. When platelets were exposed to shear stress at 37 degrees C, transmitted light intensity increased with time. Scanning electronmicroscopic examinations revealed that more prominent platelet aggregation was demonstrated when light intensity increased. Reproducible recording of SIPA was obtained when experiments were repeated using the same sample. No change in light intensity was observed when formalin-fixed platelets were sheared. Both PGE1, and anti-GPIIb/IIIa mouse monoclonal antibody, AP2, showed complete inhibition of SIPA. It is indicated that our device for continuous measurement of SIPA is an important new tool to study one aspect of platelet functions.

UI MeSH Term Description Entries
D008855 Microscopy, Electron, Scanning Microscopy in which the object is examined directly by an electron beam scanning the specimen point-by-point. The image is constructed by detecting the products of specimen interactions that are projected above the plane of the sample, such as backscattered electrons. Although SCANNING TRANSMISSION ELECTRON MICROSCOPY also scans the specimen point by point with the electron beam, the image is constructed by detecting the electrons, or their interaction products that are transmitted through the sample plane, so that is a form of TRANSMISSION ELECTRON MICROSCOPY. Scanning Electron Microscopy,Electron Scanning Microscopy,Electron Microscopies, Scanning,Electron Microscopy, Scanning,Electron Scanning Microscopies,Microscopies, Electron Scanning,Microscopies, Scanning Electron,Microscopy, Electron Scanning,Microscopy, Scanning Electron,Scanning Electron Microscopies,Scanning Microscopies, Electron,Scanning Microscopy, Electron
D009391 Nephelometry and Turbidimetry Chemical analysis based on the phenomenon whereby light, passing through a medium with dispersed particles of a different refractive index from that of the medium, is attenuated in intensity by scattering. In turbidimetry, the intensity of light transmitted through the medium, the unscattered light, is measured. In nephelometry, the intensity of the scattered light is measured, usually, but not necessarily, at right angles to the incident light beam. Turbidimetry,Nephelometry,Turbidimetry and Nephelometry
D010974 Platelet Aggregation The attachment of PLATELETS to one another. This clumping together can be induced by a number of agents (e.g., THROMBIN; COLLAGEN) and is part of the mechanism leading to the formation of a THROMBUS. Aggregation, Platelet
D010976 Platelet Count The number of PLATELETS per unit volume in a sample of venous BLOOD. Blood Platelet Count,Blood Platelet Number,Platelet Number,Blood Platelet Counts,Blood Platelet Numbers,Count, Blood Platelet,Count, Platelet,Counts, Blood Platelet,Counts, Platelet,Number, Blood Platelet,Number, Platelet,Numbers, Blood Platelet,Numbers, Platelet,Platelet Count, Blood,Platelet Counts,Platelet Counts, Blood,Platelet Number, Blood,Platelet Numbers,Platelet Numbers, Blood
D005557 Formaldehyde A highly reactive aldehyde gas formed by oxidation or incomplete combustion of hydrocarbons. In solution, it has a wide range of uses: in the manufacture of resins and textiles, as a disinfectant, and as a laboratory fixative or preservative. Formaldehyde solution (formalin) is considered a hazardous compound, and its vapor toxic. (From Reynolds, Martindale The Extra Pharmacopoeia, 30th ed, p717) Formalin,Formol,Methanal,Oxomethane
D005976 Glutaral One of the protein CROSS-LINKING REAGENTS that is used as a disinfectant for sterilization of heat-sensitive equipment and as a laboratory reagent, especially as a fixative. Glutaraldehyde,Cidex,Diswart,Gludesin,Glutardialdehyde,Glutarol,Korsolex,Novaruca,Sekumatic,Sonacide,Sporicidin
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
March 1990, Lancet (London, England),
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
August 1994, Stroke,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
September 1995, Circulation,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
January 2000, Clinical hemorheology and microcirculation,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
July 1997, Journal of cellular biochemistry,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
June 1990, [Rinsho ketsueki] The Japanese journal of clinical hematology,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
April 2016, Annals of biomedical engineering,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
January 1983, Transactions - American Society for Artificial Internal Organs,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
July 1993, Thrombosis and haemostasis,
M Fukuyama, and K Sakai, and I Itagaki, and K Kawano, and M Murata, and Y Kawai, and K Watanabe, and M Handa, and Y Ikeda
January 1986, Blood,
Copied contents to your clipboard!