The Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images. 2014

Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran ; Student Research Committee, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.

BACKGROUND Magnetic nanoparticles have been widely applied in recent years for biomedical applications. Signal intensity (SI) of magnetic resonance (MR) images depends on the concentration of nanoparticles. It is important to find the minimum concentration of iron oxide nanoparticles that produces maximum SI and determines the minimum injection dose for clinical studies. OBJECTIVE This study was performed to determine the relationship between the iron oxide nanoparticle concentration and SI using inversion recovery (IR) sequence in T1-weighted MR images. METHODS Different concentrations of carboxydextran-coated iron oxide nanoparticles 20 nm in size were prepared. In vitro MR imaging was performed with inversion times (TI) of 100-400 ms (interval of 20 ms) and IR Turbo-FLASH (Turbo fast low angle shot) pulse sequence using a 1.5 T MRI system. Then the SI produced by each concentration of nanoparticles was measured and the minimum nanoparticle concentration that led to the maximum SI was determined. Coil non-uniformity was also considered for measuring the accurate SI of each image. RESULTS The results indicate that SI depended on the concentration of nanoparticles and TI. In addition, SI increased by increasing the TIs ranging from 200 to 400 ms for all studied concentrations. The linear relationship between the nanoparticle concentrations and SI that gave a square correlation coefficient (R(2)) equal to 0.99 was seen up to 76.83 µmol Fe/L in 400 ms for long TI and 239.16 µmol Fe/L in 200 ms for short TI. CONCLUSIONS TI is an important parameter to consider in the relationship between SI and nanoparticle concentrations. An increase in TI leads to a decrease in the range of linearity.

UI MeSH Term Description Entries

Related Publications

Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
April 1998, Radiology,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
July 2014, Radiological physics and technology,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
October 2013, Japanese journal of radiology,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
July 2008, The Journal of veterinary medical science,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
January 1995, Journal of magnetic resonance imaging : JMRI,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
January 1996, Journal of magnetic resonance imaging : JMRI,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
January 2012, Radiographics : a review publication of the Radiological Society of North America, Inc,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
June 2005, Journal of magnetic resonance imaging : JMRI,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
January 2020, Journal of Korean medical science,
Hodaiseh Saharkhiz, and Nahideh Gharehaghaji, and Mahmood Nazarpoor, and Asghar Mesbahi, and Masoud Pourissa
January 1996, Academic radiology,
Copied contents to your clipboard!