Automatic control of neuromuscular block with atracurium. 1989

A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
Department of Anaesthetics, Victoria Infirmary, Glasgow.

We have developed and tested a system for providing automatic control of neuromuscular block with atracurium. The degree of neuromuscular block was monitored in the small muscles of the hand using a Datex Relaxograph, and the signal was used as the controlled variable for a proportional plus integral controller. A preloaded integral was used to shorten the period of stabilization. The system was tested in 36 patients undergoing surgery and found to produce stable block. For a target T1 of 20% of control value, the mean block was 18.7 (SD 1.3) % of baseline T1 and the mean consumption of atracurium was 5.39 (SD 1.23) micrograms kg-1 min-1. The block was sufficiently stable to act as a background for studies of pharmacological and physiological interactions with atracurium.

UI MeSH Term Description Entries
D007260 Infusion Pumps Fluid propulsion systems driven mechanically, electrically, or osmotically that are used to inject (or infuse) over time agents into a patient or experimental animal; used routinely in hospitals to maintain a patent intravenous line, to administer antineoplastic agents and other drugs in thromboembolism, heart disease, diabetes mellitus (INSULIN INFUSION SYSTEMS is also available), and other disorders. Drug Infusion Systems,Infusion Pump,Infusion Pumps, External,Infusors,Intravenous Drug Delivery System,Intravenous Drug Delivery Systems,Perfusion Pumps,Pumps, Infusion,Drug Infusion System,External Infusion Pump,External Infusion Pumps,Infusion Pump, External,Infusion System, Drug,Infusion Systems, Drug,Infusor,Perfusion Pump,Pump, External Infusion,Pump, Infusion,Pump, Perfusion,Pumps, External Infusion,Pumps, Perfusion,System, Drug Infusion,Systems, Drug Infusion
D008297 Male Males
D008838 Microcomputers Small computers using LSI (large-scale integration) microprocessor chips as the CPU (central processing unit) and semiconductor memories for compact, inexpensive storage of program instructions and data. They are smaller and less expensive than minicomputers and are usually built into a dedicated system where they are optimized for a particular application. "Microprocessor" may refer to just the CPU or the entire microcomputer. Computers, Personal,Microprocessors,Computer, Personal,Microcomputer,Microprocessor,Personal Computer,Personal Computers
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009435 Synaptic Transmission The communication from a NEURON to a target (neuron, muscle, or secretory cell) across a SYNAPSE. In chemical synaptic transmission, the presynaptic neuron releases a NEUROTRANSMITTER that diffuses across the synaptic cleft and binds to specific synaptic receptors, activating them. The activated receptors modulate specific ion channels and/or second-messenger systems in the postsynaptic cell. In electrical synaptic transmission, electrical signals are communicated as an ionic current flow across ELECTRICAL SYNAPSES. Neural Transmission,Neurotransmission,Transmission, Neural,Transmission, Synaptic
D009469 Neuromuscular Junction The synapse between a neuron and a muscle. Myoneural Junction,Nerve-Muscle Preparation,Junction, Myoneural,Junction, Neuromuscular,Junctions, Myoneural,Junctions, Neuromuscular,Myoneural Junctions,Nerve Muscle Preparation,Nerve-Muscle Preparations,Neuromuscular Junctions,Preparation, Nerve-Muscle,Preparations, Nerve-Muscle
D004576 Electromyography Recording of the changes in electric potential of muscle by means of surface or needle electrodes. Electromyogram,Surface Electromyography,Electromyograms,Electromyographies,Electromyographies, Surface,Electromyography, Surface,Surface Electromyographies
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
September 1997, Medical & biological engineering & computing,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
January 1986, Minerva anestesiologica,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
July 1989, Anaesthesia,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
June 1999, Computers and biomedical research, an international journal,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
January 1985, Annales francaises d'anesthesie et de reanimation,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
January 1990, Research in veterinary science,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
June 1989, British journal of anaesthesia,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
October 1992, Acta anaesthesiologica Scandinavica,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
March 1985, European journal of anaesthesiology,
A D MacLeod, and A J Asbury, and W M Gray, and D A Linkens
November 1997, Acta anaesthesiologica Scandinavica,
Copied contents to your clipboard!