Assessment of the scatter fraction evaluation methodology using Monte Carlo simulation techniques. 1989

D Acchiappati, and N Cerullo, and R Guzzardi
C.N.R. Institute of Clinical Physiology, Pisa, Italy.

To evaluate scatter fraction and scatter pair spatial distribution, experimental methods are generally used. These methods make use of a line source, placed along the FOV axis, inserted in a cylindrical phantom filled with air or water. The accuracy of these experimental methodologies can be tested by the use of a Monte Carlo method. In fact, the simulation allows the shape of the scatter event projection and the scatter fraction to be defined. An example of this application is the simulation package PETSI (PET SImulation). In this paper the comparison between the predicted scatter fraction and the experimentally evaluated one, obtained using an ECAT III PT 911/02 double ring whole body scanner are presented. PETSI permits additional data to be obtained: a) the true and scatter component of the energy spectrum; b) the spatial distribution, in the FOV plane, of the detected scatter events at different energy thresholds; c) the scatter to total detected events ratio; d) the predicted scatter fraction at both energy thresholds and FOV diameters. This information is very useful for optimizing both energy threshold and FOV size and to improve the accuracy of the currently used methods for the scatter fraction evaluation. Preliminary results of the predicted scatter fraction in a uniform phantom are presented.

UI MeSH Term Description Entries
D008961 Models, Structural A representation, generally small in scale, to show the structure, construction, or appearance of something. (From Random House Unabridged Dictionary, 2d ed) Model, Structural,Structural Model,Structural Models
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D012542 Scattering, Radiation The diversion of RADIATION (thermal, electromagnetic, or nuclear) from its original path as a result of interactions or collisions with atoms, molecules, or larger particles in the atmosphere or other media. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Radiation Scattering,Radiation Scatterings,Scatterings, Radiation
D014055 Tomography, Emission-Computed Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image. CAT Scan, Radionuclide,CT Scan, Radionuclide,Computerized Emission Tomography,Radionuclide Tomography, Computed,Scintigraphy, Computed Tomographic,Tomography, Radionuclide-Computed,Computed Tomographic Scintigraphy,Emission-Computed Tomography,Radionuclide Computer-Assisted Tomography,Radionuclide Computerized Tomography,Radionuclide-Computed Tomography,Radionuclide-Emission Computed Tomography,Tomography, Computerized Emission,CAT Scans, Radionuclide,CT Scans, Radionuclide,Computed Radionuclide Tomography,Computed Tomography, Radionuclide-Emission,Computer-Assisted Tomographies, Radionuclide,Computer-Assisted Tomography, Radionuclide,Computerized Tomography, Radionuclide,Emission Computed Tomography,Emission Tomography, Computerized,Radionuclide CAT Scan,Radionuclide CAT Scans,Radionuclide CT Scan,Radionuclide CT Scans,Radionuclide Computed Tomography,Radionuclide Computer Assisted Tomography,Radionuclide Computer-Assisted Tomographies,Radionuclide Emission Computed Tomography,Scan, Radionuclide CAT,Scan, Radionuclide CT,Scans, Radionuclide CAT,Scans, Radionuclide CT,Tomographic Scintigraphy, Computed,Tomographies, Radionuclide Computer-Assisted,Tomography, Computed Radionuclide,Tomography, Emission Computed,Tomography, Radionuclide Computed,Tomography, Radionuclide Computer-Assisted,Tomography, Radionuclide Computerized,Tomography, Radionuclide-Emission Computed

Related Publications

D Acchiappati, and N Cerullo, and R Guzzardi
July 2016, Journal of medical imaging (Bellingham, Wash.),
D Acchiappati, and N Cerullo, and R Guzzardi
January 1988, Medical physics,
D Acchiappati, and N Cerullo, and R Guzzardi
January 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
D Acchiappati, and N Cerullo, and R Guzzardi
August 1979, Journal of the Air Pollution Control Association,
D Acchiappati, and N Cerullo, and R Guzzardi
August 1999, Physics in medicine and biology,
D Acchiappati, and N Cerullo, and R Guzzardi
December 1985, Physics in medicine and biology,
D Acchiappati, and N Cerullo, and R Guzzardi
April 2017, Radiation protection dosimetry,
D Acchiappati, and N Cerullo, and R Guzzardi
February 2002, Radiology,
D Acchiappati, and N Cerullo, and R Guzzardi
August 2021, Zeitschrift fur medizinische Physik,
D Acchiappati, and N Cerullo, and R Guzzardi
August 2010, Physics in medicine and biology,
Copied contents to your clipboard!