The Accuracy of Single Photon Emission Computed Tomography/Computed Tomography Arthrography in Evaluating Aseptic Loosening of Hip and Knee Prostheses. 2015

Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.

Aseptic loosening represents the most common complication associated with hip and knee arthroplasty and is a common indication for surgical revision in the post-arthroplasty population. The optimal imaging methodology in evaluating clinical suspected loosening is not well-defined. Our study retrospectively evaluated nuclear medicine arthrography with hybrid single photon emission computed tomography/computed tomography (SPECT/CT) in 38 patients (21 hip, 17 knee) compared with reference standards of surgical evaluation, spontaneous resolution of symptoms without revision, or a minimum of 1 year clinical and radiographic follow-up. Our study demonstrated a sensitivity of 100%, specificity of 96.0%, PPV of 92.9%, NPV of 100%, and accuracy of 97.4% with this imaging technique suggesting utility of nuclear medicine arthrography with SPECT/CT in the clinical evaluation of suspected aseptic loosening.

UI MeSH Term Description Entries
D007719 Knee Joint A synovial hinge connection formed between the bones of the FEMUR; TIBIA; and PATELLA. Superior Tibiofibular Joint,Joint, Knee,Joint, Superior Tibiofibular,Knee Joints,Superior Tibiofibular Joints,Tibiofibular Joint, Superior
D007720 Knee Prosthesis Replacement for a knee joint. Knee Prostheses,Prostheses, Knee,Prosthesis, Knee
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001175 Arthrography Roentgenography of a joint, usually after injection of either positive or negative contrast medium. Arthrographies
D012189 Retrospective Studies Studies used to test etiologic hypotheses in which inferences about an exposure to putative causal factors are derived from data relating to characteristics of persons under study or to events or experiences in their past. The essential feature is that some of the persons under study have the disease or outcome of interest and their characteristics are compared with those of unaffected persons. Retrospective Study,Studies, Retrospective,Study, Retrospective
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
March 2020, Nuclear medicine communications,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
December 2021, The Journal of arthroplasty,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
January 2024, The Journal of arthroplasty,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
February 2021, European journal of hybrid imaging,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
January 2022, Revue medicale de Liege,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
January 1978, Acta orthopaedica Belgica,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
January 1997, International orthopaedics,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
January 1991, Acta orthopaedica Belgica,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
November 1995, Neuroimaging clinics of North America,
Jonathan T Abele, and Vimarsha G Swami, and Gordon Russell, and Edward C O Masson, and Jeffrey P Flemming
October 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Copied contents to your clipboard!