A new implantable burst generator for skeletal muscle powered aortic counterpulsation. 1989

C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
Department of Surgery, Montreal General Hospital, Quebec, Canada.

Skeletal muscle (SM) can be used for long-term circulatory assist. To generate contractions of appropriate duration and strength, SM requires bursts of electrical pulse trains. Presently, the implantable pulse train stimulator for SM assist is unable, at different heart rates, to adjust pulse burst duration or delay time, adversely affecting timing of counterpulsation. A prototype implantable microprocessor based stimulator (Medtronic Prometheus) has been developed to address this issue. The purpose of this study was to test this generator in an acute dog model. A dual chambered counterpulsation device was connected to the aorta in six dogs, using the latissimus dorsi to power the pump. The generator was connected by sensing/stimulating leads to the heart/left thoracodorsal nerve, programmed to give bursts of 2 V, 30 Hz, and pulse widths of 180 microsecs. Burst delay and duration was set as a fixed percent of the R-R interval of the EKG. The baseline aortic pressures ranged from 75/33 to 118/87 mmHg. During counterpulsation, diastolic pressure increased from 17 to 50 mmHg (30-111% increase). With changing heart rates, the pulse generator spontaneously readjusted its burst delay and duration, maintaining optimal diastolic counterpulsation without systolic interference. We conclude that this new pulse generator can stimulate SM for counterpulsation at varying heart rates, and is suitable for implantation in chronic studies.

UI MeSH Term Description Entries
D008838 Microcomputers Small computers using LSI (large-scale integration) microprocessor chips as the CPU (central processing unit) and semiconductor memories for compact, inexpensive storage of program instructions and data. They are smaller and less expensive than minicomputers and are usually built into a dedicated system where they are optimized for a particular application. "Microprocessor" may refer to just the CPU or the entire microcomputer. Computers, Personal,Microprocessors,Computer, Personal,Microcomputer,Microprocessor,Personal Computer,Personal Computers
D009132 Muscles Contractile tissue that produces movement in animals. Muscle Tissue,Muscle,Muscle Tissues,Tissue, Muscle,Tissues, Muscle
D011211 Electric Power Supplies Devices that control the supply of electric current for running electrical equipment. Power Sources,Power Supplies,Electric Power Sources,Power Sources, Electric,Power Supplies, Electric,Electric Power Source,Electric Power Supply,Power Source,Power Source, Electric,Power Supply,Power Supply, Electric,Supply, Electric Power
D004285 Dogs The domestic dog, Canis familiaris, comprising about 400 breeds, of the carnivore family CANIDAE. They are worldwide in distribution and live in association with people. (Walker's Mammals of the World, 5th ed, p1065) Canis familiaris,Dog
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006353 Heart-Assist Devices Small pumps, often implantable, designed for temporarily assisting the heart, usually the LEFT VENTRICLE, to pump blood. They consist of a pumping chamber and a power source, which may be partially or totally external to the body and activated by electromagnetic motors. Artificial Ventricle,Heart Assist Device,Heart Ventricle, Artificial,Pumps, Heart-Assist,Vascular-Assist Device,Vascular-Assist Devices,Ventricle-Assist Device,Ventricular Assist Device,Artificial Heart Ventricle,Artificial Heart Ventricles,Artificial Ventricles,Assist Device, Heart,Assist Device, Ventricular,Assist Devices, Heart,Assist Devices, Ventricular,Device, Heart Assist,Device, Heart-Assist,Device, Vascular-Assist,Device, Ventricle-Assist,Device, Ventricular Assist,Devices, Heart Assist,Devices, Heart-Assist,Devices, Vascular-Assist,Devices, Ventricle-Assist,Devices, Ventricular Assist,Heart Assist Devices,Heart Ventricles, Artificial,Heart-Assist Device,Heart-Assist Pump,Heart-Assist Pumps,Pump, Heart-Assist,Pumps, Heart Assist,Vascular Assist Device,Vascular Assist Devices,Ventricle Assist Device,Ventricle, Artificial,Ventricle, Artificial Heart,Ventricle-Assist Devices,Ventricles, Artificial,Ventricles, Artificial Heart,Ventricular Assist Devices
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D015908 Counterpulsation A technique for assisting the circulation by decreasing the afterload of the left ventricle and augmenting the diastolic pressure. It may be achieved by intra-aortic balloon, or by implanting a special pumping device in the chest, or externally by applying a negative pressure to the lower extremities during cardiac systole. Counterpulsation, External,Diastolic Counterpulsation,Counterpulsation, Diastolic,External Counterpulsation

Related Publications

C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
December 1986, Journal of cardiac surgery,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
November 1987, The Journal of thoracic and cardiovascular surgery,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
January 1990, ASAIO transactions,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
November 1991, The Journal of thoracic and cardiovascular surgery,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
November 2009, Annals of biomedical engineering,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
November 2011, IEEE transactions on bio-medical engineering,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
February 2002, The Annals of thoracic surgery,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
December 1997, The Journal of small animal practice,
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
January 1997, ASAIO journal (American Society for Artificial Internal Organs : 1992),
C M Li, and A Hill, and C Desrosiers, and P Grandjean, and R C Chiu
January 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
Copied contents to your clipboard!