Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008297 Male Males
D010388 Pelvis The space or compartment surrounded by the pelvic girdle (bony pelvis). It is subdivided into the greater pelvis and LESSER PELVIS. The pelvic girdle is formed by the PELVIC BONES and SACRUM. Pelvic Region,Region, Pelvic
D011471 Prostatic Neoplasms Tumors or cancer of the PROSTATE. Cancer of Prostate,Prostate Cancer,Cancer of the Prostate,Neoplasms, Prostate,Neoplasms, Prostatic,Prostate Neoplasms,Prostatic Cancer,Cancer, Prostate,Cancer, Prostatic,Cancers, Prostate,Cancers, Prostatic,Neoplasm, Prostate,Neoplasm, Prostatic,Prostate Cancers,Prostate Neoplasm,Prostatic Cancers,Prostatic Neoplasm
D011834 Radiation Monitoring The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. Monitoring, Radiation
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D056888 Patient Positioning Moving a patient into a specific position or POSTURE to facilitate examination, surgery, or for therapeutic purposes. Patient Positionings,Positioning, Patient,Positionings, Patient
D057918 Fiducial Markers Materials used as reference points for imaging studies. Anatomic Fiducials,Fiducial Targets,Implanted Fiducials,Anatomic Fiducial,Fiducial Marker,Fiducial Target,Fiducial, Anatomic,Fiducial, Implanted,Fiducials, Anatomic,Fiducials, Implanted,Implanted Fiducial,Marker, Fiducial,Markers, Fiducial,Target, Fiducial,Targets, Fiducial
D059629 Signal-To-Noise Ratio The comparison of the quantity of meaningful data to the irrelevant or incorrect data. Ratio, Signal-To-Noise,Ratios, Signal-To-Noise,Signal To Noise Ratio,Signal-To-Noise Ratios

Related Publications

D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
April 2020, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
September 2020, Biomedical physics & engineering express,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
December 2012, International journal of radiation oncology, biology, physics,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
May 2012, Physics in medicine and biology,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
November 2014, Medical physics,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
January 2021, Quantitative imaging in medicine and surgery,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
July 2020, Physics in medicine and biology,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
October 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
March 2017, BMC cancer,
D Wallace, and J A Ng, and P J Keall, and R T O'Brien, and P R Poulsen, and P Juneja, and J T Booth
February 2015, International journal of radiation oncology, biology, physics,
Copied contents to your clipboard!