Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium. 2015

K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 135-710, South Korea.

BACKGROUND Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. METHODS A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm(3)/s (n = 3) and 0.2 cm(3)/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. RESULTS Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm(3)/s contrast infusion protocol was better for evaluating the stent and host artery. CONCLUSIONS Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow.

UI MeSH Term Description Entries
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D002341 Carotid Artery Thrombosis Blood clot formation in any part of the CAROTID ARTERIES. This may produce CAROTID STENOSIS or occlusion of the vessel, leading to TRANSIENT ISCHEMIC ATTACK; CEREBRAL INFARCTION; or AMAUROSIS FUGAX. Thrombosis, Carotid Artery,Carotid Thrombosis,Common Carotid Artery Thrombosis,External Carotid Artery Thrombosis,Internal Carotid Artery Thrombosis,Thrombosis, Carotid,Thrombosis, Common Carotid Artery,Thrombosis, External Carotid Artery,Thrombosis, Internal Carotid Artery,Carotid Artery Thromboses
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000792 Angiography Radiography of blood vessels after injection of a contrast medium. Arteriography,Angiogram,Angiograms,Angiographies,Arteriographies
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D054893 Cone-Beam Computed Tomography Computed tomography modalities which use a cone or pyramid-shaped beam of radiation. CAT Scan, Cone-Beam,Cone-Beam CT,Tomography, Cone-Beam Computed,Tomography, Volume Computed,CT Scan, Cone-Beam,Cone-Beam Computer-Assisted Tomography,Cone-Beam Computerized Tomography,Volume CT,Volume Computed Tomography,Volumetric CT,Volumetric Computed Tomography,CAT Scan, Cone Beam,CAT Scans, Cone-Beam,CT Scan, Cone Beam,CT Scans, Cone-Beam,CT, Cone-Beam,CT, Volume,CT, Volumetric,Computed Tomography, Cone-Beam,Computed Tomography, Volume,Computed Tomography, Volumetric,Computer-Assisted Tomography, Cone-Beam,Computerized Tomography, Cone-Beam,Cone Beam CT,Cone Beam Computed Tomography,Cone Beam Computer Assisted Tomography,Cone Beam Computerized Tomography,Cone-Beam CAT Scan,Cone-Beam CAT Scans,Cone-Beam CT Scan,Cone-Beam CT Scans,Scan, Cone-Beam CAT,Scan, Cone-Beam CT,Scans, Cone-Beam CAT,Scans, Cone-Beam CT,Tomography, Cone Beam Computed,Tomography, Cone-Beam Computer-Assisted,Tomography, Cone-Beam Computerized,Tomography, Volumetric Computed

Related Publications

K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
November 2008, Radiation medicine,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
January 2016, Advances in radiation oncology,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
April 2020, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
February 2019, The British journal of radiology,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
January 2007, General dentistry,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
July 2018, Dental clinics of North America,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
September 2016, Journal of vascular surgery,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
May 2012, Medical physics,
K I Jo, and S R Kim, and J H Choi, and K H Kim, and P Jeon
April 2022, The British journal of radiology,
Copied contents to your clipboard!