Fixation for metacarpal neck fracture: a biomechanical study. 2015

Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
Division of Hand Surgery, Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, P.O. Box 980153, Richmond, VA 23298-0153 USA.

BACKGROUND There is no robust evidence of the best operative treatment for displaced unstable metacarpal neck fractures. Numerous constructs are used in the fixation of metacarpal neck fractures. Currently, two common methods are dorsal locking plate and K-wire fixation. A new metacarpal sled fixation system for metacarpal neck fracture was designed to provide fracture stability but limit dissection and avoid exposed hardware. The purpose of this study was to compare the biomechanical integrity of the metacarpal sled versus standard locking plate fixation and retrograde K-wire fixation in a simulated porcine metacarpal fracture model. METHODS Transverse metacarpal neck fractures were created in 30 porcine second metacarpals. The specimens were randomly fixed with locking plates, metacarpal sleds, or retrograde K-wires. Constructs were then loaded to failure in three-point bending. Stiffness and peak load were measured from the load-to-failure deflection curve. Data were analyzed via ANOVA, followed by Tukey-Kramer's post hoc pairwise comparison. RESULTS The K-wire group had the highest initial stiffness followed by the sled group and then the plate group. Statistical difference was only found between K-wires and plate. Peak load for the K-wire group was lowest, followed by sled, and then by plate. A statistically significant difference was observed between the peak loads of the K-wires and plate, as well as the sled and plate. However, a difference in peak load was not detected between the K-wires and sled. CONCLUSIONS For transverse metacarpal neck fractures, a metacarpal sled construct provides similar fixation to K-wires with limited dissection and without exposed hardware or the potential for soft tissue tethering. The new low profile construct using a minimally invasive technique would be suitable for unstable metacarpal neck fractures.

UI MeSH Term Description Entries

Related Publications

Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
July 2018, Journal of orthopaedic surgery and research,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
April 2023, The Journal of hand surgery, European volume,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
August 2002, Annals of plastic surgery,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
May 2017, The Journal of hand surgery,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
September 2022, Hand (New York, N.Y.),
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
March 2015, Hand (New York, N.Y.),
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
February 2021, BMC musculoskeletal disorders,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
December 2014, European journal of orthopaedic surgery & traumatology : orthopedie traumatologie,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
June 2016, Injury,
Pramote Malasitt, and John R Owen, and Marc-Antoine Tremblay, and Jennifer S Wayne, and Jonathan E Isaacs
August 2019, Der Unfallchirurg,
Copied contents to your clipboard!