An adaptive real-time beat detection method for continuous pressure signals. 2016

Xiaochang Liu, and Gaofeng Wang, and Jia Liu
School of Electronic Information, Wuhan University, Wuhan, 430072, China. xiaochang@whu.edu.cn.

A novel adaptive real-time beat detection method for pressure related signals is proposed by virtue of an enhanced mean shift (EMS) algorithm. This EMS method consists of three components: spectral estimates of the heart rate, enhanced mean shift algorithm and classification logic. The Welch power spectral density method is employed to estimate the heart rate. An enhanced mean shift algorithm is then applied to improve the morphologic features of the blood pressure signals and detect the maxima of the blood pressure signals effectively. Finally, according to estimated heart rate, the classification logic is established to detect the locations of misdetections and over detections within the accepted heart rate limits. The parameters of the algorithm are adaptively tuned for ensuring its robustness in various heart rate conditions. The performance of the EMS method is validated with expert annotations of two standard databases and a non-invasive dataset. The results from this method show that the sensitivity (Se) and positive predictivity (+P) are significantly improved (i.e., Se > 99.45 %, +P > 98.28 %, and p value 0.0474) by comparison with the existing scheme from the previously published literature.

UI MeSH Term Description Entries
D007427 Intracranial Pressure Pressure within the cranial cavity. It is influenced by brain mass, the circulatory system, CSF dynamics, and skull rigidity. Intracerebral Pressure,Subarachnoid Pressure,Intracerebral Pressures,Intracranial Pressures,Pressure, Intracerebral,Pressure, Intracranial,Pressure, Subarachnoid,Pressures, Intracerebral,Pressures, Intracranial,Pressures, Subarachnoid,Subarachnoid Pressures
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010092 Oximetry The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry. Pulse Oximetry,Oximetry, Pulse,Oximetries,Oximetries, Pulse,Pulse Oximetries
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D001795 Blood Pressure Determination Techniques used for measuring BLOOD PRESSURE. Blood Pressure Determinations,Determination, Blood Pressure
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D003657 Decision Making The process of making a selective intellectual judgment when presented with several complex alternatives consisting of several variables, and usually defining a course of action or an idea. Credit Assignment,Assignment, Credit,Assignments, Credit,Credit Assignments
D003936 Diagnosis, Computer-Assisted Application of computer programs designed to assist the physician in solving a diagnostic problem. Computer-Assisted Diagnosis,Computer Assisted Diagnosis,Computer-Assisted Diagnoses,Diagnoses, Computer-Assisted,Diagnosis, Computer Assisted

Related Publications

Xiaochang Liu, and Gaofeng Wang, and Jia Liu
October 2005, IEEE transactions on bio-medical engineering,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
July 2019, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
January 2008, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
March 1988, Medical & biological engineering & computing,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
December 2020, Optics letters,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
June 1993, The American journal of physiology,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
June 1983, IEEE transactions on bio-medical engineering,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
December 2020, Journal of personalized medicine,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
January 2015, Gait & posture,
Xiaochang Liu, and Gaofeng Wang, and Jia Liu
October 2013, Computers in biology and medicine,
Copied contents to your clipboard!