Development of a microfluidic device for cell concentration and blood cell-plasma separation. 2015

M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India.

This work presents design, fabrication and test of a microfluidic device which employs Fahraeus-Lindqvist and Zweifach-Fung effects for cell concentration and blood cell-plasma separation. The device design comprises a straight main channel with a series of branched channels placed symmetrically on both sides of the main channel. The design implements constrictions before each junction (branching point) in order to direct cells that would have migrated closer to the wall (naturally or after liquid extraction at a junction) towards the centre of the main channel. Theoretical and numerical analysis are performed for design of the microchannel network to ensure that a minimum flow rate ratio (of 2.5:1, main channel-to-side channels) is maintained at each junction and predict flow rate at the plasma outlet. The dimensions and location of the constrictions were determined using numerical simulations. The effect of presence of constrictions before the junctions was demonstrated by comparing the performances of the device with and without constrictions. To demonstrate the performance of the device, initial experiments were performed with polystyrene microbeads (10 and 15 μm size) and droplets. Finally, the device was used for concentration of HL60 cells and separation of plasma and cells in diluted blood samples. The cell concentration and blood-plasma purification efficiency was quantified using Haemocytometer and Fluorescence-Activated Cell Sorter (FACS). A seven-fold cell concentration was obtained with HL60 cells and a purification efficiency of 70 % and plasma recovery of 80 % was observed for diluted (1:20) blood sample. FACS was used to identify cell lysis and the cell viability was checked using Trypan Blue test which showed that more than 99 % cells are alive indicating the suitability of the device for practical use. The proposed device has potential to be used as a sample preparation module in lab on chip based diagnostic platforms.

UI MeSH Term Description Entries
D008863 Microspheres Small uniformly-sized spherical particles, of micrometer dimensions, frequently labeled with radioisotopes or various reagents acting as tags or markers. Latex Beads,Latex Particles,Latex Spheres,Microbeads,Bead, Latex,Beads, Latex,Latex Bead,Latex Particle,Latex Sphere,Microbead,Microsphere,Particle, Latex,Particles, Latex,Sphere, Latex,Spheres, Latex
D008962 Models, Theoretical Theoretical representations that simulate the behavior or activity of systems, processes, or phenomena. They include the use of mathematical equations, computers, and other electronic equipment. Experimental Model,Experimental Models,Mathematical Model,Model, Experimental,Models (Theoretical),Models, Experimental,Models, Theoretic,Theoretical Study,Mathematical Models,Model (Theoretical),Model, Mathematical,Model, Theoretical,Models, Mathematical,Studies, Theoretical,Study, Theoretical,Theoretical Model,Theoretical Models,Theoretical Studies
D010949 Plasma The residual portion of BLOOD that is left after removal of BLOOD CELLS by CENTRIFUGATION without prior BLOOD COAGULATION. Blood Plasma,Fresh Frozen Plasma,Blood Plasmas,Fresh Frozen Plasmas,Frozen Plasma, Fresh,Frozen Plasmas, Fresh,Plasma, Blood,Plasma, Fresh Frozen,Plasmas,Plasmas, Blood,Plasmas, Fresh Frozen
D011137 Polystyrenes Polymerized forms of styrene used as a biocompatible material, especially in dentistry. They are thermoplastic and are used as insulators, for injection molding and casting, as sheets, plates, rods, rigid forms and beads. Polystyrol,Polystyrene,Polystyrols
D001773 Blood Cells The cells found in the body fluid circulating throughout the CARDIOVASCULAR SYSTEM. Blood Corpuscles,Blood Cell,Blood Corpuscle,Cell, Blood,Cells, Blood,Corpuscle, Blood,Corpuscles, Blood
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D046210 Microfluidic Analytical Techniques Methods utilizing the principles of MICROFLUIDICS for sample handling, reagent mixing, and separation and detection of specific components in fluids. Microfluidic Analysis,Analyses, Microfluidic,Analysis, Microfluidic,Analytical Technique, Microfluidic,Analytical Techniques, Microfluidic,Microfluidic Analyses,Microfluidic Analytical Technique,Technique, Microfluidic Analytical,Techniques, Microfluidic Analytical
D056656 Lab-On-A-Chip Devices Microdevices that combine microfluidics technology with electrical and/or mechanical functions for analyzing very small fluid volumes. They consist of microchannels etched into substrates made of silicon, glass, or polymer using processes similar to photolithography. The test fluids in the channels can then interact with different elements such as electrodes, photodetectors, chemical sensors, pumps, and valves. Microchip Analytical Devices,Microfluidic Devices,Microfluidic Lab-On-A-Chip,Microfluidic Microchips,Nanochip Analytical Devices,Analytical Device, Microchip,Analytical Device, Nanochip,Analytical Devices, Microchip,Analytical Devices, Nanochip,Device, Lab-On-A-Chip,Device, Microchip Analytical,Device, Microfluidic,Device, Nanochip Analytical,Devices, Lab-On-A-Chip,Devices, Microchip Analytical,Devices, Microfluidic,Devices, Nanochip Analytical,Lab On A Chip Devices,Lab-On-A-Chip Device,Lab-On-A-Chip, Microfluidic,Lab-On-A-Chips, Microfluidic,Microchip Analytical Device,Microchip, Microfluidic,Microchips, Microfluidic,Microfluidic Device,Microfluidic Lab On A Chip,Microfluidic Lab-On-A-Chips,Microfluidic Microchip,Nanochip Analytical Device
D018922 HL-60 Cells A promyelocytic cell line derived from a patient with ACUTE PROMYELOCYTIC LEUKEMIA. HL-60 cells lack specific markers for LYMPHOID CELLS but express surface receptors for FC FRAGMENTS and COMPLEMENT SYSTEM PROTEINS. They also exhibit phagocytic activity and responsiveness to chemotactic stimuli. (From Hay et al., American Type Culture Collection, 7th ed, pp127-8) HL60 Cells,Cell, HL60,Cells, HL60,HL 60 Cells,HL-60 Cell,HL60 Cell

Related Publications

M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
July 2006, Lab on a chip,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
October 2010, Bioanalysis,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
November 2010, Artificial organs,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
January 2010, Lab on a chip,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
May 2020, Lab on a chip,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
March 2021, Micromachines,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
February 2007, Lab on a chip,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
March 2018, Ultrasonics,
M Sneha Maria, and B S Kumar, and T S Chandra, and A K Sen
March 2017, Scientific reports,
Copied contents to your clipboard!