An energy-optimized collimator design for a CZT-based SPECT camera. 2016

Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.

In single photon emission computed tomography, it is a challenging task to maintain reasonable performance using only one specific collimator for radio-tracers over a broad spectrum of diagnostic photon energies, since photon scatter and penetration in a collimator differ with the photon energy. Frequent collimator exchanges are inevitable in daily clinical SPECT imaging, which hinders throughput while subjecting the camera to operational errors and damage. Our objective is to design a collimator, which independent of the photon energy performs reasonably well for commonly used radiotracers with low- to medium-energy levels of gamma emissions. Using the Geant4 simulation toolkit, we simulated and evaluated a parallel-hole collimator mounted to a CZT detector. With the pixel-geometry-matching collimation, the pitch of the collimator hole was fixed to match the pixel size of the CZT detector throughout this work. Four variables, hole shape, hole length, hole radius/width and the source-to-collimator distance were carefully studied. Scatter and penetration of the collimator, sensitivity and spatial resolution of the system were assessed for four radionuclides including 57Co, 99 Tc, 123I and 111In, with respect to the aforementioned four variables. An optimal collimator was then decided upon such that it maximized the total relative sensitivity (TRS) for the four considered radionuclides while other performance parameters, such as scatter, penetration and spatial resolution, were benchmarked to prevalent commercial scanners and collimators. Digital phantom studies were also performed to validate the system with the optimal square-hole collimator (23 mm hole length, 1.28 mm hole width, 0.32 mm septal thickness) in terms of contrast, contrast-to-noise ratio and recovery ratio. This study demonstrates promise of our proposed energy-optimized collimator to be used in a CZT-based gamma camera, with comparable or even better imaging performance versus commercial collimators such as low-energy high resolution (LEHR) and medium energy general purpose (MEGP) collimators.

UI MeSH Term Description Entries

Related Publications

Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
January 2005, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
March 2022, Physics in medicine and biology,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
December 2004, Medical physics,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
March 1978, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
October 2023, EJNMMI physics,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
March 2015, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
March 2018, EJNMMI physics,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
July 2014, EJNMMI physics,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
August 2021, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Fenghua Weng, and Srijeeta Bagchi, and Yunlong Zan, and Qiu Huang, and Youngho Seo
December 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Copied contents to your clipboard!