Calibration coefficients of dosimeters used in mammography for various target/filter combinations. 2015

Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
University of Tsukuba. sekimoto.m.ff@u.tsukuba.ac.jp.

A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X-ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X-ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber-type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required.

UI MeSH Term Description Entries
D008327 Mammography Radiographic examination of the breast. 3D-Mammography,Digital Breast Tomosynthesis,Digital Mammography,X-ray Breast Tomosynthesis,3D Mammography,3D-Mammographies,Breast Tomosyntheses, Digital,Breast Tomosyntheses, X-ray,Breast Tomosynthesis, Digital,Breast Tomosynthesis, X-ray,Digital Breast Tomosyntheses,Digital Mammographies,Mammographies,Mammographies, Digital,Mammography, Digital,X ray Breast Tomosynthesis,X-ray Breast Tomosyntheses
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012666 Semiconductors Materials that have a limited and usually variable electrical conductivity. They are particularly useful for the production of solid-state electronic devices. Semiconductor
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations

Related Publications

Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
February 1987, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al],
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
May 1966, Health physics,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
January 2020, Journal of clinical imaging science,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
January 2012, Meditsinskaia tekhnika,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
January 1975, Journal belge de radiologie,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
June 1995, Radiology,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
October 2003, Medical physics,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
January 1972, Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
Michiharu Sekimoto, and Yoh Katoh, and Tsuguhisa Katoh
October 1994, Radiology,
Copied contents to your clipboard!