Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?. 2016

Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy

BACKGROUND Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. METHODS 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carryover, drift, sensitivity, specificity, and practicability criteria were tested. RESULTS Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was > 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter-observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). CONCLUSIONS Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.

UI MeSH Term Description Entries
D007755 Laboratories, Hospital Hospital facilities equipped to carry out investigative procedures. Hospital Laboratories,Hospital Laboratory,Laboratory, Hospital
D007958 Leukocyte Count The number of WHITE BLOOD CELLS per unit volume in venous BLOOD. A differential leukocyte count measures the relative numbers of the different types of white cells. Blood Cell Count, White,Differential Leukocyte Count,Leukocyte Count, Differential,Leukocyte Number,White Blood Cell Count,Count, Differential Leukocyte,Count, Leukocyte,Counts, Differential Leukocyte,Counts, Leukocyte,Differential Leukocyte Counts,Leukocyte Counts,Leukocyte Counts, Differential,Leukocyte Numbers,Number, Leukocyte,Numbers, Leukocyte
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D011934 Reagent Strips Narrow pieces of material impregnated or covered with a substance used to produce a chemical reaction. The strips are used in detecting, measuring, producing, etc., other substances. (From Dorland, 28th ed) Reagent Strip,Strip, Reagent,Strips, Reagent
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D003404 Creatinine Creatinine Sulfate Salt,Krebiozen,Salt, Creatinine Sulfate,Sulfate Salt, Creatinine
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D004906 Erythrocyte Count The number of RED BLOOD CELLS per unit volume in a sample of venous BLOOD. Blood Cell Count, Red,Erythrocyte Number,Red Blood Cell Count,Count, Erythrocyte,Counts, Erythrocyte,Erythrocyte Counts,Erythrocyte Numbers
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
March 1978, British journal of haematology,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
January 2009, Nefrologia : publicacion oficial de la Sociedad Espanola Nefrologia,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
January 2009, Nefrologia : publicacion oficial de la Sociedad Espanola Nefrologia,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
December 1986, American journal of clinical pathology,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
November 1995, Surgery,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
September 2017, Human reproduction (Oxford, England),
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
January 1999, Journal of obstetric, gynecologic, and neonatal nursing : JOGNN,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
January 1998, Healthcare executive,
Asmaa Ismail Ahmed, and Heba Baz, and Sarah Lotfy
January 2015, International journal of chronic obstructive pulmonary disease,
Copied contents to your clipboard!