Feasibility of external beam radiation therapy to deep-seated targets with kilovoltage x-rays. 2017

Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
Department of Physics and Astronomy, University of Victoria, PO Box 1700 ST CSC, Victoria, BC, V8W 2Y2, Canada.

OBJECTIVE Radiation therapy to deep-seated targets is typically delivered with megavoltage x-ray beams generated by medical linear accelerators or 60 Co sources. Here, we used computer simulations to design and optimize a lower energy kilovoltage x-ray source generating acceptable dose distributions to a deep-seated target. METHODS The kilovoltage arc therapy (KVAT) x-ray source was designed to treat a 4-cm diameter target located at a 10-cm depth in a 40-cm diameter homogeneous cylindrical phantom. These parameters were chosen as an example of a clinical scenario for testing the performance of the kilovoltage source. A Monte Carlo (MC) model of the source was built in the EGSnrc/BEAMnrc code and source parameters, such as beam energy, tungsten anode thickness, beam filtration, number of collimator holes, collimator hole size and thickness, and source extent were varied. Dose to the phantom was calculated in the EGSnrc/DOSXYZnrc code for varying treatment parameters, such as the source-to-axis distance and the treatment arc angle. The quality of dose distributions was quantified by means of target-to-skin ratio and dose output expressed in D50 (50% isodose line) for a 30-min irradiation in the homogeneous phantom as well as a lung phantom. Additionally, a patient KVAT dose distribution to a left pararenal lesion (~1.6 cm in diameter) was calculated and compared to a 15 MV volumetric modulated arc therapy (VMAT) plan. RESULTS In the design of the KVAT x-ray source, the beam energy, beam filtration, collimator hole size, source-to-isocenter distance, and treatment arc had the largest effect on the source output and the quality of dose distributions. For the 4-cm target at 10-cm depth, the optimized KVAT dose distribution generated a conformal plan with target-to-skin ratio of 5.1 and D50 in 30 min of 24.1 Gy in the homogeneous phantom. In the lung phantom, a target-to-skin ratio of 7.5 and D50 in 30 min of 25.3 Gy were achieved. High dose conformity of the 200 kV KVAT left pararenal plan was comparable to the 15 MV VMAT plan. The volume irradiated to at least 10% (<240 cGy) of the prescription dose was 2.2 × larger in the 200 kV KVAT plan than in the 15 MV VMAT plan, but considered clinically insignificant. CONCLUSIONS This study demonstrated that conformal treatments of deep-seated targets were achievable with kilovoltage x-rays with dose distributions comparable to MV beams. However, due to the larger volumes irradiated to clinically tolerated low doses, KVAT x-ray source usage for deep-seated lesions will be further evaluated to determine optimal target size.

UI MeSH Term Description Entries
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011879 Radiotherapy Dosage The total amount of radiation absorbed by tissues as a result of radiotherapy. Dosage, Radiotherapy,Dosages, Radiotherapy,Radiotherapy Dosages
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D003198 Computer Simulation Computer-based representation of physical systems and phenomena such as chemical processes. Computational Modeling,Computational Modelling,Computer Models,In silico Modeling,In silico Models,In silico Simulation,Models, Computer,Computerized Models,Computer Model,Computer Simulations,Computerized Model,In silico Model,Model, Computer,Model, Computerized,Model, In silico,Modeling, Computational,Modeling, In silico,Modelling, Computational,Simulation, Computer,Simulation, In silico,Simulations, Computer
D005240 Feasibility Studies Studies to determine the advantages or disadvantages, practicability, or capability of accomplishing a projected plan, study, or project. Feasibility Study,Studies, Feasibility,Study, Feasibility
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014964 X-Ray Therapy Medical treatment involving the use of controlled amounts of X-Rays. Roentgenotherapy,Therapy, X Ray,Therapy, Xray,Xray Therapy,Roentgenotherapies,Therapies, X Ray,Therapies, X-Ray,Therapies, Xray,Therapy, X-Ray,X Ray Therapies,X Ray Therapy,X-Ray Therapies,Xray Therapies
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
January 2014, Journal of X-ray science and technology,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
January 1992, International journal of radiation oncology, biology, physics,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
January 1999, Cardiovascular radiation medicine,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
March 2007, Physics in medicine and biology,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
March 2012, Clinical oncology (Royal College of Radiologists (Great Britain)),
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
February 2019, Health physics,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
October 1988, Gan no rinsho. Japan journal of cancer clinics,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
October 2012, International journal of radiation oncology, biology, physics,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
January 1977, International journal of radiation oncology, biology, physics,
Magdalena Bazalova-Carter, and Michael D Weil, and Dylan Yamabe Breitkreutz, and Brian P Wilfley, and Edward E Graves
January 2018, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Copied contents to your clipboard!