Comparing the Fracture Resistance of Alternatively Engineered Zirconia Abutments with Original Equipment Manufactured Abutments with Different Implant Connection Designs. 2017

Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi

Aftermarket computer-aided design/computer-assisted manufacture (CAD/CAM) milled zirconia (Zr) abutments were recently introduced with minimal independent research regarding their fracture resistance. Third-party manufacturers often alter the original equipment manufacturers' (OEM) design with unknown effects on fracture resistance. These alterations include elimination of the titanium insert with subsequent introduction of Zr into the implant, changes to connection designs and shapes, and/or alterations to prosthetic screw design. This in vitro study compares the static load fracture resistance and mode of failure of alternatively engineered Zr abutments with those of prefabricated (OEM) Zr abutments with internal, external, and conical connections. Twenty Zr stock abutments (five per group) from OEMs were selected to demonstrate fracture resistance of external hex, internal connection, and conical connection implant designs (control groups). Atlantis abutments (Dentsply) (test group) were manufactured by means of CAD/CAM to match the OEM abutments (control groups). All samples had full-coverage all-ceramic crowns luted to the abutments. Static load fracture resistance was evaluated with an Instron test device. Modes of abutment failure were evaluated using both light and scanning electron microscopy. A Welch two-sample t test evaluated the OEM control groups vs the Atlantis test groups. Static load to failure (N) for each representative control group vs test group revealed (1) conical design OEM (387 N) vs Atlantis (211 N) (P < .011), (2) external-hex OEM (408 N) vs Atlantis (218 N) (P < .035), (3) trilobe internal connection OEM (430 N) vs Atlantis (260 N) (P < .014), and (4) internal connection OEM (448 N) vs Atlantis (244 N) (P < .02). Atlantis CAD/CAM Zr abutments demonstrated static fracture loads lower than those of their OEM counterparts. Failure modes were Zr fractures in the conical and external hex groups. The internal connection groups demonstrated a mixed mode of failure, with screw head fracture 100% of the failures in the internal Zr connection group. The trilobe internal connection group exhibited screw-head fracture in two of five samples and Zr fracture in the remaining three samples. Clinicians should consider avoiding the alternatively engineered Atlantis Zr abutment for restoration of posterior single teeth in cases in which occlusal forces may exceed 350 to 400 N.

UI MeSH Term Description Entries

Related Publications

Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
April 2020, The Journal of oral implantology,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
September 2019, The Journal of prosthetic dentistry,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
October 2019, Journal of prosthodontics : official journal of the American College of Prosthodontists,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
October 2020, European journal of dentistry,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
January 2009, Journal of prosthodontics : official journal of the American College of Prosthodontists,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
August 2014, The Journal of prosthetic dentistry,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
April 2019, The journal of advanced prosthodontics,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
February 2015, Journal of prosthodontics : official journal of the American College of Prosthodontists,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
March 2011, Dental materials : official publication of the Academy of Dental Materials,
Joseph M Jarman, and Techkouhie Hamalian, and Anthony P Randi
June 2022, The Journal of oral implantology,
Copied contents to your clipboard!