Multi-purpose ECG telemetry system. 2017

Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
School of Electrical Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11120, Belgrade, Serbia. maroufmail@gmail.com.

BACKGROUND The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. METHODS In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. RESULTS We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results of both short-term post-event recorder and 12-leads golden standard ECG recorder. CONCLUSIONS The proposed multi-purpose ECG device allows physicians to choose the working mode of the same device according to the patient status. The proposed device was designed to allow patients to manage the technical requirements of both working modes. Post-event short-term ECG recording using the proposed design provide physicians reliable three ECG leads with direct symptom-rhythm correlation.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D002675 Child, Preschool A child between the ages of 2 and 5. Children, Preschool,Preschool Child,Preschool Children
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005260 Female Females
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
January 1970, Obstetrics and gynecology,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
July 1974, Nursing,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
June 1997, IEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
February 1979, IEEE transactions on bio-medical engineering,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
January 1979, Biotelemetry and patient monitoring,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
March 1976, Biomedical engineering,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
May 1981, British journal of hospital medicine,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
July 2000, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation,
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
September 1974, Deutsche medizinische Wochenschrift (1946),
Mohamed Marouf, and Goran Vukomanovic, and Lazar Saranovac, and Miroslav Bozic
January 1987, Veterinarno-meditsinski nauki,
Copied contents to your clipboard!