Evaluation of Compressive Strength and Sorption/Solubility of Four Luting Cements. 2017

Tavangar Ms, and Jafarpur D, and Bagheri R
Department of Dental Materials, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.

BACKGROUND Compressive strength (CS) and sorption/solubility of the luting cements are two associated factors. Searching a correlation between sorption/solubility and compressive strength of various luting cements is required. OBJECTIVE To measure the water sorption/solubility, and compressive strength of three resin-based and one conventional glass ionomer (CGI) luting cement after 1 and 24 h of immersion in distilled water and to determine if there is any correlation between those properties found. METHODS Four luting cements were investigated. For each material, 10 disc shaped specimens were prepared for measuring the sorption/solubility. The specimens were cured according to the manufacturer's instructions, and the sorption/solubility were measured in accordance with the ISO 4049's. For testing the compression strength, for each material 16 cylindrical specimens were prepared by insertion of cements into a stainless steel split mould. The specimens were cured, divided into groups of 8, and then stored in distilled water at (37 ± 1)°C for 1 and 24 h. The test was performed using the universal testing machine, the maximum load was recorded and CS was calculated. The data were analysed using SPSS software version 18. One-way ANOVA, post-hoc Tukey's test and Pearson's correlation coefficient were performed. RESULTS G-CEM had the highest mean CS (153.60± 25.15) and CGI luting had the lowest CS (21.36±5.37) (p <0.001). After 24 h, mean CS values showed an increase for almost all materials except for RelyXTM U200 which showed a slight reduction. However, no statistically significant difference was founded (all p > 0.05). The lowest mean sorption/solubility value was for RelyXTM U200 and Panavia F, and the highest for CGI luting (all p < 0.001). CONCLUSIONS The compressive strength of all cements did not necessarily increase after 24 h and varied depending on the materials. There was a strong reverse correlation between sorption and CS values after both 1 and 24 h immersion. It may be practical for clinician to use those cements with the less sorption / solubility and more stable compression strength over time.

UI MeSH Term Description Entries

Related Publications

Tavangar Ms, and Jafarpur D, and Bagheri R
January 2000, Operative dentistry,
Tavangar Ms, and Jafarpur D, and Bagheri R
September 2008, Dental materials journal,
Tavangar Ms, and Jafarpur D, and Bagheri R
January 1990, Archivio stomatologico,
Tavangar Ms, and Jafarpur D, and Bagheri R
January 2015, Bio-medical materials and engineering,
Tavangar Ms, and Jafarpur D, and Bagheri R
June 2016, Journal of dentistry (Shiraz, Iran),
Tavangar Ms, and Jafarpur D, and Bagheri R
February 2003, Journal of dentistry,
Tavangar Ms, and Jafarpur D, and Bagheri R
August 2017, Journal of investigative and clinical dentistry,
Tavangar Ms, and Jafarpur D, and Bagheri R
March 2008, Quintessence international (Berlin, Germany : 1985),
Tavangar Ms, and Jafarpur D, and Bagheri R
March 1981, The Journal of prosthetic dentistry,
Tavangar Ms, and Jafarpur D, and Bagheri R
April 2020, Acta medica academica,
Copied contents to your clipboard!