Primary sulcus implantation of a diffractive multifocal pseudophakic piggyback intraocular lens. 2018

Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
From Department of Ophthalmology (Cassagne, Porterie, Chapotot, Soler, Malecaze, Fournié), Purpan Hospital, Toulouse, and Helios Clinic (Gauthier), Saint Jean de Luz, France. Electronic address: cassagnemyriam@gmail.com.

OBJECTIVE To evaluate the efficacy and safety of the combined implantation of a monofocal intraocular lens (IOL) in the capsular bag with a diffractive multifocal IOL designed for sulcus placement (Reverso). METHODS Purpan Hospital, Toulouse, and Helios Clinic, Saint-Jean-de-Luz, France. METHODS Prospective case series. METHODS The multifocal IOL piggyback IOL was implanted in the sulcus during cataract surgery. Visual acuity, defocus curve, contrast sensitivity, IOL positioning, and patient satisfaction were assessed with 1-year follow-ups. RESULTS Fifty-four eyes of 27 patients were included. At 1-month, monocular uncorrected distance (UDVA) and near (UNVA) visual acuities were 0.13 logarithm of the minimum angle of resolution (logMAR) ± 0.18 (SD) and 0.20 ± 0.16 logMAR, respectively. Binocular UDVA and UNVA were 0.03 ± 0.06 and 0.12 ± 0.08 logMAR, respectively. At 1 year, the mean monocular logMAR UDVA, corrected distance visual acuity, UNVA, and corrected near visual acuity were 0.10 ± 0.11, 0.02 ± 0.06, 0.18 ± 0.12, and 0.13 ± 0.08, respectively. The defocus curve and contrast sensitivity values were comparable to those obtained with other multifocal IOLs. On Scheimpflug imaging, the mean distance between the sulcus multifocal IOL and the monofocal IOL was 517 ± 141 μm. At 1 year, ultrasound biomicroscopy showed an annular fibrosis of the anterior capsule in 94.4% of the eyes. Complications included 1 posttraumatic IOL decentration and 1 slight corectopia. Eighty-nine percent of patients reported satisfaction. CONCLUSIONS The piggyback implantation of this multifocal IOL seemed to be safe and effective. It might provide similar results as a primary in-the-bag multifocal IOL, with the advantage of reversibility that might extend primary or secondary implantation.

UI MeSH Term Description Entries
D007429 Intraocular Pressure The pressure of the fluids in the eye. Ocular Tension,Intraocular Pressures,Ocular Tensions,Pressure, Intraocular,Pressures, Intraocular,Tension, Ocular,Tensions, Ocular
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D011795 Surveys and Questionnaires Collections of data obtained from voluntary subjects. The information usually takes the form of answers to questions, or suggestions. Community Survey,Nonrespondent,Questionnaire,Questionnaires,Respondent,Survey,Survey Method,Survey Methods,Surveys,Baseline Survey,Community Surveys,Methodology, Survey,Nonrespondents,Questionnaire Design,Randomized Response Technique,Repeated Rounds of Survey,Respondents,Survey Methodology,Baseline Surveys,Design, Questionnaire,Designs, Questionnaire,Methods, Survey,Questionnaire Designs,Questionnaires and Surveys,Randomized Response Techniques,Response Technique, Randomized,Response Techniques, Randomized,Survey, Baseline,Survey, Community,Surveys, Baseline,Surveys, Community,Techniques, Randomized Response
D002452 Cell Count The number of CELLS of a specific kind, usually measured per unit volume or area of sample. Cell Density,Cell Number,Cell Counts,Cell Densities,Cell Numbers,Count, Cell,Counts, Cell,Densities, Cell,Density, Cell,Number, Cell,Numbers, Cell
D004728 Endothelium, Corneal Single layer of large flattened cells covering the surface of the cornea. Anterior Chamber Epithelium,Corneal Endothelium,Endothelium, Anterior Chamber,Epithelium, Anterior Chamber,Anterior Chamber Endothelium
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000075542 Multifocal Intraocular Lenses Artificially implanted lenses that direct light toward distant and near focal points allowing clear vision for a range of distances. Accommodating IOLs,Accommodating Intraocular Lens,Accommodating Intraocular Lenses,Multifocal IOLs,Multifocal Intraocular Lens,Accommodating IOL,IOL, Accommodating,IOL, Multifocal,IOLs, Accommodating,Intraocular Lens, Accommodating,Intraocular Lens, Multifocal,Intraocular Lenses, Accommodating,Multifocal IOL

Related Publications

Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
April 2014, Journal of refractive surgery (Thorofare, N.J. : 1995),
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
November 2006, Journal of cataract and refractive surgery,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
February 2007, Journal of cataract and refractive surgery,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
December 2009, Journal of cataract and refractive surgery,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
December 2007, Journal of cataract and refractive surgery,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
September 2001, Journal of cataract and refractive surgery,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
March 2021, European journal of ophthalmology,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
December 1991, Annals of ophthalmology,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
August 2007, Ophthalmology,
Myriam Cassagne, and Marie Porterie, and Laurent Gauthier, and Eric Chapotot, and Vincent Soler, and François Malecaze, and Pierre Fournié
February 2000, Current opinion in ophthalmology,
Copied contents to your clipboard!