[Assessment of Left Ventricular Diastolic Function Using ECG-gated Myocardial Perfusion SPECT in Small Heart: Comparison with Ultrasound Echocardiography]. 2018

Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
Division of Radiology and Nuclear Medicine, Sapporo Medical University Hospital.

Assessment of left ventricular (LV) diastolic function is important because it is possible to detect early sign of myocardial ischemia by this assessment. The purpose of this study was to compare between electrocardiogram (ECG) -gated myocardial perfusion single photon emission computed tomography (G-SPECT) and ultrasound echocardiography in assessment of LV diastolic function in the small heart (SH). The study population consisted of 144 patients who underwent both G-SPECT and ultrasound echocardiography. Peak filling rate (PFR), one-third mean filling rate (1/3 MFR) and the ratio of time to PFR to the RR interval (TPFR/RR) were calculated by quantitative gated SPECT (QGS) and heart risk view-F (HRV-F). Peak early mitral annular velocity (e') was used as the reference standard of LV diastolic function. There were 33 patients with end-systolic volume (ESV) of ≤10 ml (SH10), 51 patients with ESV of 11-20 ml (SH 20) and 60 patients with ESV of >20 ml (normal-sized heart: NH). In SH10, PFR calculated by QGS was not correlated with e'. However, that by HRV-F was significantly correlated with e' (r=0.47, p=0.006). On the other hand, 1/3 MFR and TPFR/RR calculated by QGS and HRV-F were not correlated with e' in SH10 and SH20. PFR, 1/3 MFR and TPFR/RR calculated by QGS and HRV-F were correlated with e' in NH.

UI MeSH Term Description Entries
D003971 Diastole Post-systolic relaxation of the HEART, especially the HEART VENTRICLES. Diastoles
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013318 Stroke Volume The amount of BLOOD pumped out of the HEART per beat, not to be confused with cardiac output (volume/time). It is calculated as the difference between the end-diastolic volume and the end-systolic volume. Ventricular Ejection Fraction,Ventricular End-Diastolic Volume,Ventricular End-Systolic Volume,Ejection Fraction, Ventricular,Ejection Fractions, Ventricular,End-Diastolic Volume, Ventricular,End-Diastolic Volumes, Ventricular,End-Systolic Volume, Ventricular,End-Systolic Volumes, Ventricular,Fraction, Ventricular Ejection,Fractions, Ventricular Ejection,Stroke Volumes,Ventricular Ejection Fractions,Ventricular End Diastolic Volume,Ventricular End Systolic Volume,Ventricular End-Diastolic Volumes,Ventricular End-Systolic Volumes,Volume, Stroke,Volume, Ventricular End-Diastolic,Volume, Ventricular End-Systolic,Volumes, Stroke,Volumes, Ventricular End-Diastolic,Volumes, Ventricular End-Systolic
D015899 Tomography, Emission-Computed, Single-Photon A method of computed tomography that uses radionuclides which emit a single photon of a given energy. The camera is rotated 180 or 360 degrees around the patient to capture images at multiple positions along the arc. The computer is then used to reconstruct the transaxial, sagittal, and coronal images from the 3-dimensional distribution of radionuclides in the organ. The advantages of SPECT are that it can be used to observe biochemical and physiological processes as well as size and volume of the organ. The disadvantage is that, unlike positron-emission tomography where the positron-electron annihilation results in the emission of 2 photons at 180 degrees from each other, SPECT requires physical collimation to line up the photons, which results in the loss of many available photons and hence degrades the image. CAT Scan, Single-Photon Emission,CT Scan, Single-Photon Emission,Radionuclide Tomography, Single-Photon Emission-Computed,SPECT,Single-Photon Emission-Computed Tomography,Tomography, Single-Photon, Emission-Computed,Single-Photon Emission CT Scan,Single-Photon Emission Computer-Assisted Tomography,Single-Photon Emission Computerized Tomography,CAT Scan, Single Photon Emission,CT Scan, Single Photon Emission,Emission-Computed Tomography, Single-Photon,Radionuclide Tomography, Single Photon Emission Computed,Single Photon Emission CT Scan,Single Photon Emission Computed Tomography,Single Photon Emission Computer Assisted Tomography,Single Photon Emission Computerized Tomography,Tomography, Single-Photon Emission-Computed
D016277 Ventricular Function, Left The hemodynamic and electrophysiological action of the left HEART VENTRICLE. Its measurement is an important aspect of the clinical evaluation of patients with heart disease to determine the effects of the disease on cardiac performance. Left Ventricular Function,Function, Left Ventricular,Functions, Left Ventricular,Left Ventricular Functions,Ventricular Functions, Left

Related Publications

Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
January 2013, International heart journal,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
January 2001, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
October 2008, The Journal of the Association of Physicians of India,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
January 1999, Kaku igaku. The Japanese journal of nuclear medicine,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
September 2005, Annals of nuclear medicine,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
October 2010, Annals of nuclear medicine,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
September 2023, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
March 2008, Circulation journal : official journal of the Japanese Circulation Society,
Taiki Chono, and Masahisa Onoguchi, and Akiyoshi Hashimoto
November 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,