Non-contrast computed tomography for the diagnosis of non-traumatic subarachnoid hemorrhage. 2018

Yerko Suazo, and Gabriel Rada
Facultad de Medicina, Universidad de Chile, Santiago, Chile; Proyecto Epistemonikos, Santiago, Chile.

BACKGROUND Subarachnoid hemorrhage is a neurosurgical emergency that requires timely diagnosis due to its severity and the existence of therapeutic measures that are effective when carried out in time. The most used diagnostic sequence to rule it out is computed tomography without contrast which, if negative, is followed by lumbar puncture. However, it has been suggested that a negative non-contrast computed tomography (without blood) may rule out the diagnosis. METHODS To answer this question we used Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We extracted data from the systematic reviews, reanalyzed data of primary studies, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. CONCLUSIONS We identified three systematic reviews including nine studies. We concluded the diagnostic accuracy of non-contrast computed tomography is probably very high, but the clinical impact of relying only on this test has not yet been evaluated.

UI MeSH Term Description Entries
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013129 Spinal Puncture Tapping fluid from the subarachnoid space in the lumbar region, usually between the third and fourth lumbar vertebrae. Lumbar Puncture,Spinal Tap,Lumbar Punctures,Puncture, Lumbar,Puncture, Spinal,Punctures, Lumbar,Punctures, Spinal,Spinal Punctures,Spinal Taps,Tap, Spinal,Taps, Spinal
D013345 Subarachnoid Hemorrhage Bleeding into the intracranial or spinal SUBARACHNOID SPACE, most resulting from INTRACRANIAL ANEURYSM rupture. It can occur after traumatic injuries (SUBARACHNOID HEMORRHAGE, TRAUMATIC). Clinical features include HEADACHE; NAUSEA; VOMITING, nuchal rigidity, variable neurological deficits and reduced mental status. Hemorrhage, Subarachnoid,Perinatal Subarachnoid Hemorrhage,Subarachnoid Hemorrhage, Aneurysmal,Subarachnoid Hemorrhage, Spontaneous,SAH (Subarachnoid Hemorrhage),Subarachnoid Hemorrhage, Intracranial,Aneurysmal Subarachnoid Hemorrhage,Aneurysmal Subarachnoid Hemorrhages,Hemorrhage, Aneurysmal Subarachnoid,Hemorrhage, Intracranial Subarachnoid,Hemorrhage, Perinatal Subarachnoid,Hemorrhage, Spontaneous Subarachnoid,Hemorrhages, Aneurysmal Subarachnoid,Hemorrhages, Intracranial Subarachnoid,Hemorrhages, Perinatal Subarachnoid,Hemorrhages, Spontaneous Subarachnoid,Hemorrhages, Subarachnoid,Intracranial Subarachnoid Hemorrhage,Intracranial Subarachnoid Hemorrhages,Perinatal Subarachnoid Hemorrhages,SAHs (Subarachnoid Hemorrhage),Spontaneous Subarachnoid Hemorrhage,Spontaneous Subarachnoid Hemorrhages,Subarachnoid Hemorrhage, Perinatal,Subarachnoid Hemorrhages,Subarachnoid Hemorrhages, Aneurysmal,Subarachnoid Hemorrhages, Intracranial,Subarachnoid Hemorrhages, Perinatal,Subarachnoid Hemorrhages, Spontaneous
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D016208 Databases, Factual Extensive collections, reputedly complete, of facts and data garnered from material of a specialized subject area and made available for analysis and application. The collection can be automated by various contemporary methods for retrieval. The concept should be differentiated from DATABASES, BIBLIOGRAPHIC which is restricted to collections of bibliographic references. Databanks, Factual,Data Banks, Factual,Data Bases, Factual,Data Bank, Factual,Data Base, Factual,Databank, Factual,Database, Factual,Factual Data Bank,Factual Data Banks,Factual Data Base,Factual Data Bases,Factual Databank,Factual Databanks,Factual Database,Factual Databases

Related Publications

Yerko Suazo, and Gabriel Rada
May 2020, Revue neurologique,
Yerko Suazo, and Gabriel Rada
February 2006, Journal of neuroradiology = Journal de neuroradiologie,
Yerko Suazo, and Gabriel Rada
July 2022, The American journal of emergency medicine,
Yerko Suazo, and Gabriel Rada
January 2001, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association,
Yerko Suazo, and Gabriel Rada
January 2009, Annals of emergency medicine,
Yerko Suazo, and Gabriel Rada
October 2013, Annals of emergency medicine,
Yerko Suazo, and Gabriel Rada
August 1977, Neuroradiology,
Yerko Suazo, and Gabriel Rada
November 2021, The Journal of emergency medicine,
Copied contents to your clipboard!