[A new method for calibration of electrophysiological recording systems (author's transl)]. 1977

I Wilmanns, and R Stodtmeister

The method described in this paper permits determination of amplification, band-pass properties, and electrode impedance in electrophysiological experimental setups. The battery powered test-signal generator drives square-wave current pulses through a 2 ohm resistance, which acts as a source of 100 muV p-p pulses. The 2 ohm resistor is wired in series with one of the electrode leads and remains there permanently. For calibration of the above-mentioned properties, one need only turn the generator on, without changing the measurement setup. By observing the shape of the square waves after passing through the system, it is possible to judge the band-pass characteristics of the entire system. Electrode impedance may be measured by putting a (variable) resistor in parallel with the preamplifier input. The test signal current is of the same order of magnitude as currents from biological signal sources. This method makes working with electrophysiological measurement systems which are used in electroretinography, electrooculography, and recording of visually-evoked cortical potentials in ophthalmology much easier.

UI MeSH Term Description Entries
D009991 Oscillometry The measurement of frequency or oscillation changes. Oscillometries
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D004596 Electroretinography Recording of electric potentials in the retina after stimulation by light. Electroretinographies
D005071 Evoked Potentials Electrical responses recorded from nerve, muscle, SENSORY RECEPTOR, or area of the CENTRAL NERVOUS SYSTEM following stimulation. They range from less than a microvolt to several microvolts. The evoked potential can be auditory (EVOKED POTENTIALS, AUDITORY), somatosensory (EVOKED POTENTIALS, SOMATOSENSORY), visual (EVOKED POTENTIALS, VISUAL), or motor (EVOKED POTENTIALS, MOTOR), or other modalities that have been reported. Event Related Potential,Event-Related Potentials,Evoked Potential,N100 Evoked Potential,P50 Evoked Potential,N1 Wave,N100 Evoked Potentials,N2 Wave,N200 Evoked Potentials,N3 Wave,N300 Evoked Potentials,N4 Wave,N400 Evoked Potentials,P2 Wave,P200 Evoked Potentials,P50 Evoked Potentials,P50 Wave,P600 Evoked Potentials,Potentials, Event-Related,Event Related Potentials,Event-Related Potential,Evoked Potential, N100,Evoked Potential, N200,Evoked Potential, N300,Evoked Potential, N400,Evoked Potential, P200,Evoked Potential, P50,Evoked Potential, P600,Evoked Potentials, N100,Evoked Potentials, N200,Evoked Potentials, N300,Evoked Potentials, N400,Evoked Potentials, P200,Evoked Potentials, P50,Evoked Potentials, P600,N1 Waves,N2 Waves,N200 Evoked Potential,N3 Waves,N300 Evoked Potential,N4 Waves,N400 Evoked Potential,P2 Waves,P200 Evoked Potential,P50 Waves,P600 Evoked Potential,Potential, Event Related,Potential, Event-Related,Potential, Evoked,Potentials, Event Related,Potentials, Evoked,Potentials, N400 Evoked,Related Potential, Event,Related Potentials, Event,Wave, N1,Wave, N2,Wave, N3,Wave, N4,Wave, P2,Wave, P50,Waves, N1,Waves, N2,Waves, N3,Waves, N4,Waves, P2,Waves, P50
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000669 Amplifiers, Electronic Electronic devices that increase the magnitude of a signal's power level or current. Amplifier, Electronic,Electronic Amplifier,Electronic Amplifiers
D014793 Visual Cortex Area of the OCCIPITAL LOBE concerned with the processing of visual information relayed via VISUAL PATHWAYS. Area V2,Area V3,Area V4,Area V5,Associative Visual Cortex,Brodmann Area 18,Brodmann Area 19,Brodmann's Area 18,Brodmann's Area 19,Cortical Area V2,Cortical Area V3,Cortical Area V4,Cortical Area V5,Secondary Visual Cortex,Visual Cortex Secondary,Visual Cortex V2,Visual Cortex V3,Visual Cortex V3, V4, V5,Visual Cortex V4,Visual Cortex V5,Visual Cortex, Associative,Visual Motion Area,Extrastriate Cortex,Area 18, Brodmann,Area 18, Brodmann's,Area 19, Brodmann,Area 19, Brodmann's,Area V2, Cortical,Area V3, Cortical,Area V4, Cortical,Area V5, Cortical,Area, Visual Motion,Associative Visual Cortices,Brodmanns Area 18,Brodmanns Area 19,Cortex Secondary, Visual,Cortex V2, Visual,Cortex V3, Visual,Cortex, Associative Visual,Cortex, Extrastriate,Cortex, Secondary Visual,Cortex, Visual,Cortical Area V3s,Extrastriate Cortices,Secondary Visual Cortices,V3, Cortical Area,V3, Visual Cortex,V4, Area,V4, Cortical Area,V5, Area,V5, Cortical Area,V5, Visual Cortex,Visual Cortex Secondaries,Visual Cortex, Secondary,Visual Motion Areas

Related Publications

I Wilmanns, and R Stodtmeister
December 1979, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae,
I Wilmanns, and R Stodtmeister
February 1974, Biomedizinische Technik. Biomedical engineering,
I Wilmanns, and R Stodtmeister
January 1977, Giornale italiano di cardiologia,
I Wilmanns, and R Stodtmeister
June 1976, Kokubyo Gakkai zasshi. The Journal of the Stomatological Society, Japan,
I Wilmanns, and R Stodtmeister
January 1981, Sheng li ke xue jin zhan [Progress in physiology],
I Wilmanns, and R Stodtmeister
January 1974, Bulletin de physio-pathologie respiratoire,
I Wilmanns, and R Stodtmeister
June 1975, Kokyu to junkan. Respiration & circulation,
I Wilmanns, and R Stodtmeister
July 1980, Zeitschrift fur Kinderchirurgie und Grenzgebiete,
I Wilmanns, and R Stodtmeister
September 1973, Klinische Monatsblatter fur Augenheilkunde,
I Wilmanns, and R Stodtmeister
July 1981, Klinische Monatsblatter fur Augenheilkunde,
Copied contents to your clipboard!