Computer image processing of electron micrographs of biological structures with helical symmetry. 1988

M Stewart
Medical Research Council, Laboratory of Molecular Biology, Cambridge, England.

Methods are described for the analysis of electron micrographs of biological objects with helical symmetry and for the production of three-dimensional models of these structures using computer image reconstruction methods. Fourier-based processing of one- and two-dimensionally ordered planar arrays is described by way of introduction, before analysing the special properties of helices and their transforms. Conceiving helical objects as a sum of helical waves (analogous to the sum of planar waves used to describe a planar crystal) is shown to facilitate analysis and enable three-dimensional models to be produced, often from a single view of the object. The corresponding Fourier transform of such a sum of helical waves consists of a sum of Bessel function terms along layer lines. Special problems deriving from the overlapping along layer lines of terms of different Bessel order are discussed, and methods to separate these terms, based on analysing a number of different azimuthal views of the object by least squares, are described. Corrections to alleviate many technical and specimen-related problems are discussed in conjunction with a consideration of the computer methods used to actually process an image. A range of examples of helical objects, including viruses, microtubules, flagella, actin, and myosin filaments, are discussed to illustrate the range of problems that can be addressed by computer reconstruction methods.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D008854 Microscopy, Electron Microscopy using an electron beam, instead of light, to visualize the sample, thereby allowing much greater magnification. The interactions of ELECTRONS with specimens are used to provide information about the fine structure of that specimen. In TRANSMISSION ELECTRON MICROSCOPY the reactions of the electrons that are transmitted through the specimen are imaged. In SCANNING ELECTRON MICROSCOPY an electron beam falls at a non-normal angle on the specimen and the image is derived from the reactions occurring above the plane of the specimen. Electron Microscopy
D005407 Flagella A whiplike motility appendage present on the surface cells. Prokaryote flagella are composed of a protein called FLAGELLIN. Bacteria can have a single flagellum, a tuft at one pole, or multiple flagella covering the entire surface. In eukaryotes, flagella are threadlike protoplasmic extensions used to propel flagellates and sperm. Flagella have the same basic structure as CILIA but are longer in proportion to the cell bearing them and present in much smaller numbers. (From King & Stansfield, A Dictionary of Genetics, 4th ed) Flagellum
D005583 Fourier Analysis Analysis based on the mathematical function first formulated by Jean-Baptiste-Joseph Fourier in 1807. The function, known as the Fourier transform, describes the sinusoidal pattern of any fluctuating pattern in the physical world in terms of its amplitude and its phase. It has broad applications in biomedicine, e.g., analysis of the x-ray crystallography data pivotal in identifying the double helical nature of DNA and in analysis of other molecules, including viruses, and the modified back-projection algorithm universally used in computerized tomography imaging, etc. (From Segen, The Dictionary of Modern Medicine, 1992) Fourier Series,Fourier Transform,Analysis, Cyclic,Analysis, Fourier,Cyclic Analysis,Analyses, Cyclic,Cyclic Analyses,Series, Fourier,Transform, Fourier
D014780 Viruses Minute infectious agents whose genomes are composed of DNA or RNA, but not both. They are characterized by a lack of independent metabolism and the inability to replicate outside living host cells. Animal Viruses,Zoophaginae,Animal Virus,Virus,Virus, Animal,Viruses, Animal

Related Publications

M Stewart
August 2008, Ultramicroscopy,
M Stewart
January 1996, Journal of structural biology,
M Stewart
December 1977, Proceedings of the National Academy of Sciences of the United States of America,
M Stewart
January 1970, Transactions of the Royal Society of Tropical Medicine and Hygiene,
Copied contents to your clipboard!