Central Composite Design for Dispersive Liquid-liquid Microextraction of 25-hydroxy-cholecalciferol in Human Serum. 2019

Afsaneh Mollahosseini, and Marzieh Kamankesh, and Abdorreza Mohammadi
Research Laboratory of Spectroscopy & Micro and Nano Extraction, Department of Chemistry, Iran University of Science and Technology, Tehran, Iran.

The human body's vitamin D levels are determined by measuring the level of 25-hydroxy-vitamin D3 (25-OH-vitamin D3) in human serum. In this research, a fast, simple, efficient and highly sensitive low-density solvent based on dispersive liquid-liquid microextraction (DLLME) was employed for the successful determination of 25-OH-vitamin D3 from complex human serum matrices. Reversed phase high-performance liquid chromatography was used as a powerful technique. The important parameters in the low-density solvent-DLLME method were optimized using response surface methodology based on central composite design. The calibration curves displayed a high level of linearity (R2 > 0.997) for 25-OH-vitamin D3 in the range of 2-500 ng mL-1. The limit of detection and limit of quantitation were 0.6 ng mL-1 and 1.9 ng mL-1, respectively. The relative standard deviation for the seven analyses was 7.1%. The relative recoveries of vitamin D3 in spiked human serum samples were between 85% and 97%. The amount of 25-OH-vitamin D3 in samples was determined using the proposed method and acceptable results were reported.

UI MeSH Term Description Entries
D012107 Research Design A plan for collecting and utilizing data so that desired information can be obtained with sufficient precision or so that an hypothesis can be tested properly. Experimental Design,Data Adjustment,Data Reporting,Design, Experimental,Designs, Experimental,Error Sources,Experimental Designs,Matched Groups,Methodology, Research,Problem Formulation,Research Methodology,Research Proposal,Research Strategy,Research Technics,Research Techniques,Scoring Methods,Adjustment, Data,Adjustments, Data,Data Adjustments,Design, Research,Designs, Research,Error Source,Formulation, Problem,Formulations, Problem,Group, Matched,Groups, Matched,Matched Group,Method, Scoring,Methods, Scoring,Problem Formulations,Proposal, Research,Proposals, Research,Reporting, Data,Research Designs,Research Proposals,Research Strategies,Research Technic,Research Technique,Scoring Method,Source, Error,Sources, Error,Strategies, Research,Strategy, Research,Technic, Research,Technics, Research,Technique, Research,Techniques, Research
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015652 25-Hydroxyvitamin D 2 9,10-Secoergosta-5,7,10(19),22-tetraene-3,25-diol. Biologically active metabolite of vitamin D2 which is more active in curing rickets than its parent. The compound is believed to attach to the same receptor as vitamin D2 and 25-hydroxyvitamin D3. 25-Hydroxyergocalciferol,25-Hydroxycalciferol,25-Hydroxyvitamin D2,9,10-Secoergosta-5,7,10(19),22-tetraene-3 beta,25-diol,Ercalcidiol,25 Hydroxycalciferol,25 Hydroxyergocalciferol,25 Hydroxyvitamin D 2,25 Hydroxyvitamin D2
D016014 Linear Models Statistical models in which the value of a parameter for a given value of a factor is assumed to be equal to a + bx, where a and b are constants. The models predict a linear regression. Linear Regression,Log-Linear Models,Models, Linear,Linear Model,Linear Regressions,Log Linear Models,Log-Linear Model,Model, Linear,Model, Log-Linear,Models, Log-Linear,Regression, Linear,Regressions, Linear
D056148 Chromatography, Reverse-Phase A chromatography technique in which the stationary phase is composed of a non-polar substance with a polar mobile phase, in contrast to normal-phase chromatography in which the stationary phase is a polar substance with a non-polar mobile phase. Chromatography, Reversed-Phase Liquid,Reversed-Phase Chromatography,Reversed-Phase Liquid Chromatography,Reverse-Phase Chromatography,Reverse-Phase Liquid Chromatography,Chromatography, Reverse Phase,Chromatography, Reversed-Phase,Reverse Phase Chromatography,Reversed Phase Chromatography
D057230 Limit of Detection Concentration or quantity that is derived from the smallest measure that can be detected with reasonable certainty for a given analytical procedure. Limits of Detection,Detection Limit,Detection Limits
D059627 Liquid Phase Microextraction Miniaturized methods of liquid-liquid extraction. Liquid-Liquid Microextraction,Micro Liquid Phase Extraction,Micro Liquid-Liquid Extraction,Extraction, Micro Liquid-Liquid,Extractions, Micro Liquid-Liquid,Liquid Liquid Microextraction,Liquid Phase Microextractions,Liquid-Liquid Extraction, Micro,Liquid-Liquid Extractions, Micro,Liquid-Liquid Microextractions,Micro Liquid Liquid Extraction,Micro Liquid-Liquid Extractions,Microextraction, Liquid Phase,Microextraction, Liquid-Liquid,Microextractions, Liquid Phase,Microextractions, Liquid-Liquid,Phase Microextraction, Liquid,Phase Microextractions, Liquid

Related Publications

Afsaneh Mollahosseini, and Marzieh Kamankesh, and Abdorreza Mohammadi
June 2013, Journal of separation science,
Afsaneh Mollahosseini, and Marzieh Kamankesh, and Abdorreza Mohammadi
July 1982, Postgraduate medical journal,
Afsaneh Mollahosseini, and Marzieh Kamankesh, and Abdorreza Mohammadi
September 2013, Analytical and bioanalytical chemistry,
Afsaneh Mollahosseini, and Marzieh Kamankesh, and Abdorreza Mohammadi
March 2014, Journal of chromatography. A,
Copied contents to your clipboard!