Comparison of five automated urine sediment analyzers with manual microscopy for accurate identification of urine sediment. 2019

Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.

Background While the introduction of automated urine analyzers is expected to reduce the labor involved, turnaround time and potential assay variations, microscopic examination remains the "gold standard" for the analysis of urine sediments. In this study, we evaluated the analytical and diagnostic performance of five recently introduced automated urine sediment analyzers. Methods A total of 1016 samples were examined using five automated urine sediment analyzers and manual microscopy. Concordance of results from each automated analyzer and manual microscopy were evaluated. In addition, image and microscopic review rates of each system were investigated. Results The proportional bias for red blood cells (RBCs), white blood cells (WBCs) and squamous epithelial cells in the automated urine sediment analyzers were within ±20% of values obtained using the manual microscope, except in the cases of RBCs and WBCs analyzed using URiSCAN PlusScope and Iris iQ200SPRINT, respectively. The sensitivities of Roche Cobas® u 701 and Siemens UAS800 for pathologic casts (73.6% and 81.1%, respectively) and crystals (62.2% and 49.5%, respectively) were high, along with high image review rates (24.6% and 25.2%, respectively). The detection rates for crystals, casts and review rates can be changed for the Sysmex UF-5000 platform according to cut-off thresholds. Conclusions Each automated urine sediment analyzer has certain distinct features, in addition to the common advantages of reducing the burden of manual processing. Therefore, laboratory physicians are encouraged to understand these features, and to utilize each system in appropriate ways, considering clinical algorithms and laboratory workflow.

UI MeSH Term Description Entries
D008853 Microscopy The use of instrumentation and techniques for visualizing material and details that cannot be seen by the unaided eye. It is usually done by enlarging images, transmitted by light or electron beams, with optical or magnetic lenses that magnify the entire image field. With scanning microscopy, images are generated by collecting output from the specimen in a point-by-point fashion, on a magnified scale, as it is scanned by a narrow beam of light or electrons, a laser, a conductive probe, or a topographical probe. Compound Microscopy,Hand-Held Microscopy,Light Microscopy,Optical Microscopy,Simple Microscopy,Hand Held Microscopy,Microscopy, Compound,Microscopy, Hand-Held,Microscopy, Light,Microscopy, Optical,Microscopy, Simple
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations
D001681 Biological Assay A method of measuring the effects of a biologically active substance using an intermediate in vivo or in vitro tissue or cell model under controlled conditions. It includes virulence studies in animal fetuses in utero, mouse convulsion bioassay of insulin, quantitation of tumor-initiator systems in mouse skin, calculation of potentiating effects of a hormonal factor in an isolated strip of contracting stomach muscle, etc. Bioassay,Assay, Biological,Assays, Biological,Biologic Assay,Biologic Assays,Assay, Biologic,Assays, Biologic,Bioassays,Biological Assays
D016482 Urinalysis Examination of urine by chemical, physical, or microscopic means. Routine urinalysis usually includes performing chemical screening tests, determining specific gravity, observing any unusual color or odor, screening for bacteriuria, and examining the sediment microscopically. Urinalyses

Related Publications

Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
July 2013, Journal of clinical laboratory analysis,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
January 2020, Clinical chemistry and laboratory medicine,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
August 2016, Practical laboratory medicine,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
October 2016, Biochemia medica,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
March 2024, Practical laboratory medicine,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
September 2007, Clinica chimica acta; international journal of clinical chemistry,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
August 2005, Clinica chimica acta; international journal of clinical chemistry,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
January 2008, Journal of clinical laboratory analysis,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
December 2016, Clinical laboratory,
Jooyoung Cho, and Kyeong Jin Oh, and Beom Chan Jeon, and Sang-Guk Lee, and Jeong-Ho Kim
February 2018, Journal of clinical laboratory analysis,
Copied contents to your clipboard!