Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography-A phantom study. 2019

Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
School of Health Sciences, University of Salford, Salford, M6 6PU, United Kingdom. Electronic address: a.h.m.a.mohammedali@edu.salford.ac.uk.

OBJECTIVE Within paediatric pelvis imaging there is a lack of systematic dose optimisation studies which consider age and size variations. This paper presents data from dose optimisation studies using digital radiography and pelvis phantoms representing 1 and 5-year-old children. METHODS Dose optimisation included assessments of image quality and radiation dose. Systematic variations using a factorial design for acquisition factors (kVp, mAs, source-detector distance [SDD] and filtration) were undertaken to acquire AP pelvis X-ray images. Perceptual image quality was assessed using a relative and absolute visual grading assessment (VGA) method. Radiation doses were measured by placing a dosimeter at the radiographic centring point on the surface of each phantom. Statistical analyses for determining the optimised parameters included main effects analysis. RESULTS Optimised techniques, with diagnostically acceptable image quality, for each paediatric age were: 1-year-old; 65 kVp, 2 mAs and 115 cm SDD, while, 5-year-old; 62 kVp, 8 mAs and 130 cm SDD both included 1 mm Al +0.1 mm Cu additional filtration. The main effect analysis identified situations in which image quality and radiation dose increased or decreased, except for kVp which showed peak image quality when exposure factors were increased. A set of minimum mAs values for producing diagnostic image quality were identified. Increasing SDD, unlike the other exposure factors, showed no trends for producing non-diagnostic images. CONCLUSIONS The factorial design provided an opportunity to identify suitable acquisition factors. This study provided a method for investigating the combined effect of multiple acquisition parameters on image quality and radiation dose for children.

UI MeSH Term Description Entries
D007223 Infant A child between 1 and 23 months of age. Infants
D010388 Pelvis The space or compartment surrounded by the pelvic girdle (bony pelvis). It is subdivided into the greater pelvis and LESSER PELVIS. The pelvic girdle is formed by the PELVIC BONES and SACRUM. Pelvic Region,Region, Pelvic
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002675 Child, Preschool A child between the ages of 2 and 5. Children, Preschool,Preschool Child,Preschool Children
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
May 2016, European radiology,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
February 2020, European radiology experimental,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
January 2005, Radiation protection dosimetry,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
October 2020, Radiography (London, England : 1995),
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
October 2002, The British journal of radiology,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
June 2016, Radiation protection dosimetry,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
May 2018, Radiography (London, England : 1995),
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
January 2005, Radiation protection dosimetry,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
January 2012, Clinical imaging,
Ali Mohammed Ali, and Peter Hogg, and Mohamed Abuzaid, and Andrew England
January 2024, Radiography (London, England : 1995),
Copied contents to your clipboard!