OBJECTIVE Monte Carlo (MC) algorithms offer accurate modeling of dose calculation by simulating the transport and interactions of many particles through the patient geometry. However, given their random nature, the resulting dose distributions have statistical uncertainty (noise), which prevents making reliable clinical decisions. This issue is partly addressable using a huge number of simulated particles but is computationally expensive as it results in significantly greater computation times. Therefore, there is a trade-off between the computation time and the noise level in MC dose maps. In this work, we address the mitigation of noise inherent to MC dose distributions using dilated U-Net - an encoder-decoder-styled fully convolutional neural network, which allows fast and fully automated denoising of whole-volume dose maps. METHODS We use mean squared error (MSE) as loss function to train the model, where training is done in 2D and 2.5D settings by considering a number of adjacent slices. Our model is trained on proton therapy MC dose distributions of different tumor sites (brain, head and neck, liver, lungs, and prostate) acquired from 35 patients. We provide the network with input MC dose distributions simulated using particles while keeping particles as reference. RESULTS After training, our model successfully denoises new MC dose maps. On average (averaged over five patients with different tumor sites), our model recovers of 55.99 Gy from the noisy MC input of 49.51 Gy, whereas the low noise MC (reference) offers 56.03 Gy. We observed a significant reduction in average RMSE (thresholded >10% max ref) for reference vs denoised (1.25 Gy) than reference vs input (16.96 Gy) leading to an improvement in signal-to-noise ratio (ISNR) by 18.06 dB. Moreover, the inference time of our model for a dose distribution is less than 10 s vs 100 min (MC simulation using particles). CONCLUSIONS We propose an end-to-end fully convolutional network that can denoise Monte Carlo dose distributions. The networks provide comparable qualitative and quantitative results as the MC dose distribution simulated with particles, offering a significant reduction in computation time.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D016571 Neural Networks, Computer A computer architecture, implementable in either hardware or software, modeled after biological neural networks. Like the biological system in which the processing capability is a result of the interconnection strengths between arrays of nonlinear processing nodes, computerized neural networks, often called perceptrons or multilayer connectionist models, consist of neuron-like units. A homogeneous group of units makes up a layer. These networks are good at pattern recognition. They are adaptive, performing tasks by example, and thus are better for decision-making than are linear learning machines or cluster analysis. They do not require explicit programming. Computational Neural Networks,Connectionist Models,Models, Neural Network,Neural Network Models,Neural Networks (Computer),Perceptrons,Computational Neural Network,Computer Neural Network,Computer Neural Networks,Connectionist Model,Model, Connectionist,Model, Neural Network,Models, Connectionist,Network Model, Neural,Network Models, Neural,Network, Computational Neural,Network, Computer Neural,Network, Neural (Computer),Networks, Computational Neural,Networks, Computer Neural,Networks, Neural (Computer),Neural Network (Computer),Neural Network Model,Neural Network, Computational,Neural Network, Computer,Neural Networks, Computational,Perceptron
D059629 Signal-To-Noise Ratio The comparison of the quantity of meaningful data to the irrelevant or incorrect data. Ratio, Signal-To-Noise,Ratios, Signal-To-Noise,Signal To Noise Ratio,Signal-To-Noise Ratios
D035501 Uncertainty The condition in which reasonable knowledge regarding risks, benefits, or the future is not available.

Related Publications

Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
May 2003, Physics in medicine and biology,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
September 2007, Physics in medicine and biology,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
July 2000, Physics in medicine and biology,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
September 2003, Physics in medicine and biology,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
August 1997, Medical physics,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
September 2002, Physics in medicine and biology,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
May 2000, Medical physics,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
October 2002, Medical physics,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
August 2014, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
Umair Javaid, and Kevin Souris, and Damien Dasnoy, and Sheng Huang, and John A Lee
July 2014, Journal of applied clinical medical physics,
Copied contents to your clipboard!