[Accuracy of three intraoral scans for primary impressions of edentulous jaws]. 2020

Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
Center of Digital Dentistry, Faculty of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health & Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Diseases, Beijing 100081, China.

OBJECTIVE To provide a reference for using intraoral scanners for making clinical diagnostic dentures of edentulous jaws by comparing the accuracy of three intraoral scanners for primary impression and jaw relation record of edentulous jaws. METHODS This study contained 6 primary impressions of the edentulous patients. Each of the impressions consisted of the maxillary primary impression, the mandibular primary impression and the jaw relation record. For each of them, a dental cast scanner (Dentscan Y500) was used to obtain stereolithography (STL) data as reference scan, and then three intraoral scanners including i500, Trios 3 and CEREC Primescan were used for three times to obtain STL data as experiment groups. In Geomagic Studio 2013 software, trueness was obtained by comparing experiment groups with the reference scan, and the precision was obtained from intragroup comparisons. Registered maxillary data of the intraoral scan with reference scan, the morphological error of jaw relation record was obtained by comparing jaw relation record of the intraoral scan with the reference scan. Registered mandibular data with jaw relation record of intraoral scan and the displacement of the jaw position were evaluated. Independent samples t test and Mann-Whitney U test in the SPSS 20.0 statistical software were used to statistically analyze the trueness, precision and morphological error of jaw relation record of three intraoral scanners. The Bland-Altman diagram was used to evaluate the consistency of the jaw relationship measured by the three intraoral scanners. RESULTS The trueness of i500, Trios 3 and CEREC Primescan scanners was (182.34±101.21) μm, (145.21±71.73) μm, and (78.34±34.79) μm for maxilla; (106.42±21.63) μm, and 95.08 (63.08) μm, (78.45±42.77) μm for mandible. There was no significant difference in trueness of the three scanners when scanning the maxilla and mandible(P>0.05). The precision of the three scanners was 147.65 (156.30) μm, (147.54±83.33) μm, and 40.30 (32.80) μm for maxilla; (90.96±30.77) μm, (53.73±23.56) μm, and 37.60 (93.93) μm for mandible. The precision of CEREC Primescan scanner was significantly better than that of the other two scanners for maxilla (P<0.05). Trios 3 and CEREC Primescan scanners were significantly better than i500 scanner for mandible (P<0.05). The precision of the i500 and Trios 3 scanners for mandible was superior to maxilla (P<0.05). The upper limit of 95% confidence intervals of trueness and precision of three scanners for both maxilla and mandible were within ±300 μm which was clinically accepted. The morphological error of jaw relation record of the three scanners was (337.68±128.54) μm, (342.89±195.41) μm, and (168.62±88.35) μm. The 95% confidence intervals of i500 and Trios 3 scanners were over 300 μm. CEREC Primescan scanner was significantly superior to i500 scanner(P<0.05).The displacement of the jaw position of the three scanners was (0.83±0.56) mm, (0.80±0.45) mm, and (0.91±0.75) mm for vertical dimension; (0.79±0.58) mm, (0.62±0.18) mm, and (0.53±0.53) mm for anterior and posterior directions; (0.95±0.59) mm, (0.69±0.45) mm, and (0.60±0.22) mm for left and right directions. The displacement of the jaw position of the three scanners in vertical dimension, anterior and posterior directions and the left and right directions were within the 95% consistency limit. CONCLUSIONS Three intraoral scanners showed good trueness and precision. The i500 and Trios 3 scanners had more errors in jaw relation record, but they were used as primary jaw relation record. It is suggested that three intraoral scanners can be used for obtaining digital data to make diagnostic dentures and individual trays, reducing possible deforming or crack when sending impressions from clinic to laboratory.

UI MeSH Term Description Entries
D007575 Jaw, Edentulous The total absence of teeth from either the mandible or the maxilla, but not both. Total absence of teeth from both is MOUTH, EDENTULOUS. Partial absence of teeth in either is JAW, EDENTULOUS, PARTIALLY. Edentulous Jaw,Edentulous Jaws,Jaws, Edentulous
D003761 Dental Impression Technique Procedure of producing an imprint or negative likeness of the teeth and/or edentulous areas. Impressions are made in plastic material which becomes hardened or set while in contact with the tissue. They are later filled with plaster of Paris or artificial stone to produce a facsimile of the oral structures present. Impressions may be made of a full complement of teeth, of areas where some teeth have been removed, or in a mouth from which all teeth have been extracted. (Illustrated Dictionary of Dentistry, 1982) Dental Impression Technic,Dental Impression Technics,Dental Impression Techniques,Impression Technic, Dental,Impression Technics, Dental,Impression Technique, Dental,Impression Techniques, Dental,Technic, Dental Impression,Technics, Dental Impression,Technique, Dental Impression,Techniques, Dental Impression
D003765 Models, Dental Presentation devices used for patient education and technique training in dentistry. Dental Models,Dental Model,Model, Dental
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D017076 Computer-Aided Design The use of computers for designing and/or manufacturing of anything, including drugs, surgical procedures, orthotics, and prosthetics. CAD-CAM,Computer-Aided Manufacturing,Computer-Assisted Design,Computer-Assisted Manufacturing,Computer Aided Design,Computer Aided Manufacturing,Computer Assisted Design,Computer Assisted Manufacturing,Computer-Aided Designs,Computer-Assisted Designs,Design, Computer-Aided,Design, Computer-Assisted,Designs, Computer-Aided,Designs, Computer-Assisted,Manufacturing, Computer-Aided,Manufacturing, Computer-Assisted
D021621 Imaging, Three-Dimensional The process of generating three-dimensional images by electronic, photographic, or other methods. For example, three-dimensional images can be generated by assembling multiple tomographic images with the aid of a computer, while photographic 3-D images (HOLOGRAPHY) can be made by exposing film to the interference pattern created when two laser light sources shine on an object. Computer-Assisted Three-Dimensional Imaging,Imaging, Three-Dimensional, Computer Assisted,3-D Image,3-D Imaging,Computer-Generated 3D Imaging,Three-Dimensional Image,Three-Dimensional Imaging, Computer Generated,3 D Image,3 D Imaging,3-D Images,3-D Imagings,3D Imaging, Computer-Generated,3D Imagings, Computer-Generated,Computer Assisted Three Dimensional Imaging,Computer Generated 3D Imaging,Computer-Assisted Three-Dimensional Imagings,Computer-Generated 3D Imagings,Image, 3-D,Image, Three-Dimensional,Images, 3-D,Images, Three-Dimensional,Imaging, 3-D,Imaging, Computer-Assisted Three-Dimensional,Imaging, Computer-Generated 3D,Imaging, Three Dimensional,Imagings, 3-D,Imagings, Computer-Assisted Three-Dimensional,Imagings, Computer-Generated 3D,Imagings, Three-Dimensional,Three Dimensional Image,Three Dimensional Imaging, Computer Generated,Three-Dimensional Images,Three-Dimensional Imaging,Three-Dimensional Imaging, Computer-Assisted,Three-Dimensional Imagings,Three-Dimensional Imagings, Computer-Assisted

Related Publications

Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
February 2020, The Journal of prosthetic dentistry,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
October 2021, The journal of advanced prosthodontics,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
May 2018, The Journal of prosthetic dentistry,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
January 2020, The Chinese journal of dental research,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
October 1975, Die Quintessenz der Zahntechnik,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
October 2023, Scientific reports,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
May 1965, Revista de la Asociacion Odontologica Argentina,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
January 2016, PloS one,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
July 1968, Revista. Circulo Argentino de Odontologia,
Y Cao, and J K Chen, and K H Deng, and Y Wang, and Y C Sun, and Y J Zhao
March 2024, The journal of evidence-based dental practice,
Copied contents to your clipboard!