Steam sterilization chemical indicators are not adequate for monitoring real steam sterilization cycles. 2020

Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
Cardinal Health; prlaranjeira@gmail.com.

Chemical indicators are commonly used in hospitals to monitor steam sterilization conditions, indicating that medical devices are safe to be used. The results are stored for future evidence in the event of an infection incident root cause analysis. This type of indicator is also becoming an option for cycle monitoring in pharmaceutical steam sterilizers, improving cycle control. They are constructed and tested according to published standards, but contradictory results between chemical indicators and cycle printouts have a critical impact on process control. We found that type 6 chemical indicators used in steam sterilizer cycles did not perform according to their intended use, showing an ″approved″ result in a ″failed″ cycle (a false positive). This study demonstrated that type 6 chemical indicator specifications are not adequate for monitoring steam sterilizers. A change in standards is therefore needed.

UI MeSH Term Description Entries

Related Publications

Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
January 1984, Medical instrumentation,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
January 1975, Bulletin of the Parenteral Drug Association,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
February 1980, Bollettino chimico farmaceutico,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
June 1972, Zentralblatt fur Bakteriologie, Parasitenkunde, Infektionskrankheiten und Hygiene. Erste Abteilung Originale. Reihe B: Hygiene, praventive Medizin,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
December 2004, American journal of infection control,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
December 2017, The Journal of hospital infection,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
January 1972, Bulletin of the Parenteral Drug Association,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
January 1991, Journal of healthcare materiel management,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
January 1978, Journal of the Parenteral Drug Association,
Paulo R Laranjeira, and Jeane A G Bronzatti, and Rafael Q Souza, and Kazuko U Graziano
December 1996, Infection control and hospital epidemiology,
Copied contents to your clipboard!