Quantitative evaluation of tomographic 201-thallium myocardial scintigraphy. 1988

J Palmer, and O Pahlm, and T White, and K Lyttkens
Department of Clinical Physiology, Lasarettet, University of Lund, Sweden.

Myocardial 201Tl emission computed tomography was performed on 25 normal subjects and 27 patients with angiographically significant coronary artery disease. A semi-automatic computer program was designed to define the left ventricular myocardial volume in all short axis sections. Within this volume the relative mean myocardial pixel count was calculated. This parameter was found to separate the 2 patient groups with a sensitivity of at least 81% at a specificity of 100%.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D012984 Software Sequential operating programs and data which instruct the functioning of a digital computer. Computer Programs,Computer Software,Open Source Software,Software Engineering,Software Tools,Computer Applications Software,Computer Programs and Programming,Computer Software Applications,Application, Computer Software,Applications Software, Computer,Applications Softwares, Computer,Applications, Computer Software,Computer Applications Softwares,Computer Program,Computer Software Application,Engineering, Software,Open Source Softwares,Program, Computer,Programs, Computer,Software Application, Computer,Software Applications, Computer,Software Tool,Software, Computer,Software, Computer Applications,Software, Open Source,Softwares, Computer Applications,Softwares, Open Source,Source Software, Open,Source Softwares, Open,Tool, Software,Tools, Software
D013794 Thallium Radioisotopes Unstable isotopes of thallium that decay or disintegrate emitting radiation. Tl atoms with atomic weights 198-202, 204, and 206-210 are thallium radioisotopes. Radioisotopes, Thallium
D014055 Tomography, Emission-Computed Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image. CAT Scan, Radionuclide,CT Scan, Radionuclide,Computerized Emission Tomography,Radionuclide Tomography, Computed,Scintigraphy, Computed Tomographic,Tomography, Radionuclide-Computed,Computed Tomographic Scintigraphy,Emission-Computed Tomography,Radionuclide Computer-Assisted Tomography,Radionuclide Computerized Tomography,Radionuclide-Computed Tomography,Radionuclide-Emission Computed Tomography,Tomography, Computerized Emission,CAT Scans, Radionuclide,CT Scans, Radionuclide,Computed Radionuclide Tomography,Computed Tomography, Radionuclide-Emission,Computer-Assisted Tomographies, Radionuclide,Computer-Assisted Tomography, Radionuclide,Computerized Tomography, Radionuclide,Emission Computed Tomography,Emission Tomography, Computerized,Radionuclide CAT Scan,Radionuclide CAT Scans,Radionuclide CT Scan,Radionuclide CT Scans,Radionuclide Computed Tomography,Radionuclide Computer Assisted Tomography,Radionuclide Computer-Assisted Tomographies,Radionuclide Emission Computed Tomography,Scan, Radionuclide CAT,Scan, Radionuclide CT,Scans, Radionuclide CAT,Scans, Radionuclide CT,Tomographic Scintigraphy, Computed,Tomographies, Radionuclide Computer-Assisted,Tomography, Computed Radionuclide,Tomography, Emission Computed,Tomography, Radionuclide Computed,Tomography, Radionuclide Computer-Assisted,Tomography, Radionuclide Computerized,Tomography, Radionuclide-Emission Computed

Related Publications

J Palmer, and O Pahlm, and T White, and K Lyttkens
January 1984, Radiobiologia, radiotherapia,
J Palmer, and O Pahlm, and T White, and K Lyttkens
February 1984, International journal of cardiology,
J Palmer, and O Pahlm, and T White, and K Lyttkens
May 1982, ZFA. Zeitschrift fur Allgemeinmedizin,
J Palmer, and O Pahlm, and T White, and K Lyttkens
January 1985, American heart journal,
J Palmer, and O Pahlm, and T White, and K Lyttkens
April 1990, Meditsinskaia radiologiia,
J Palmer, and O Pahlm, and T White, and K Lyttkens
March 1983, Kaku igaku. The Japanese journal of nuclear medicine,
J Palmer, and O Pahlm, and T White, and K Lyttkens
March 1987, Archives des maladies du coeur et des vaisseaux,
J Palmer, and O Pahlm, and T White, and K Lyttkens
January 1987, Cardiovascular and interventional radiology,
J Palmer, and O Pahlm, and T White, and K Lyttkens
April 1977, Fortschritte der Medizin,
J Palmer, and O Pahlm, and T White, and K Lyttkens
August 1994, Rontgenpraxis; Zeitschrift fur radiologische Technik,
Copied contents to your clipboard!