Application of Sysmex XN-Series Automated Haematology Analyser in the Rapid Detection of Malaria. 2020

Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
Department of Laboratory Medicine, All India Institute of Medical Sciences, New Delhi, 110029 India.

Malaria, an important parasitic disease worldwide, still has diagnostic challenges in the laboratory. Many studies have been conducted on the detection ability of haematology analysers for malaria. We evaluated the Sysmex XN-series analyser as a tool for detection of malaria by analysing the leukocyte cell population data (LCPD), scattergrams and associated Flow Cytometry Standard (FCS) data from both the WNR (white cell nucleated) and WDF (white cell differential) channels. 1281 clinically suspected cases of malaria were screened for malaria by peripheral blood smear examination and were run in the Sysmex XN-1000 for analysis of haematological parameter data, LCPD, all the scattergrams and FCS data. 1281 clinically suspected cases of malaria were screened for malaria by peripheral blood smear examination and were run in the Sysmex XN-1000 for analysis of haematological parameter data, LCPD, all the scattergrams and FCS data. 48 cases had malarial parasite on microscopy; of which, 41 cases were of Plasmodium vivax, 6 cases of Plasmodium falciparum and 1 case of mixed infection. 46 malaria-positive samples showed certain patterns of clusters in the scattergrams of both WDF and WNR channels. A case with only a few ring forms of P. vivax and another with very low parasite load having only gametocyte of P. falciparum didn't show the distinctive cluster. The most distinctive clusters for all other cases were seen in WNR (SFL-SSC) and WNR (SSC-FSC) scattergrams. FCS data for the same were analysed to gate for those events. The gated events correlated (Spearman ρ = 0.77, p < 0.01) with the parasite load of the patients. By observing the scattergrams and different parameters in the Sysmex XN-series analyser, malaria can be detected from the analyser itself.

UI MeSH Term Description Entries

Related Publications

Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
October 2020, Journal of clinical pathology,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
December 2017, International journal of laboratory hematology,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
January 2019, Malaria journal,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
January 1989, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
May 1991, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
August 2001, Clinical and laboratory haematology,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
October 2009, International journal of laboratory hematology,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
January 2011, Indian journal of medical sciences,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
September 2022, Malaria journal,
Aparna Ningombam, and Abhirup Sarkar, and Shreyam Acharya, and Anita Chopra, and Kundan Kumar, and Arulselvi Subramanian
March 2024, Practical laboratory medicine,
Copied contents to your clipboard!