Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma. 2020

Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
Shanghai Xuhui Central Hospital / Zhongshan- Xuhui Hospital, Fudan University, Shanghai 200031, China; Shanghai Engineering Research Center of Phase I Clinical Research & Quality Consistency Evaluation for Drugs, Shanghai 200031, China.

A simple, rapid and accurate method for quantitative analysis of a highly selective phosphodiesterase-5 inhibitor (PDE5), TPN171 by high performance liquid chromatography and tandem mass spectrometry in human plasma was proposed and validated successfully using D3-TPN171 as internal standards (ISTD). An aliquot of 100 μL of plasma was mixed with internal standard and was precipitated with acetonitrile. Gradient elution was performed on a ACQUITY HSS T3 column (50 × 2.1 mm, 1.8 μm) coupled with a ACQUITY column in-line filter at 40℃, by 5 mM ammonium acetate in water containing 0.1 % formic acid and 0.1 % formic acid in acetonitrile as the mobile phase. The total analytical run time was 3.5 min. The analyte was monitored using multiple reaction monitoring (MRM) scan in positive polarity mode. The ion transition was m/z 442.2→113.2 and 445.2→116.2 for TPN171 and D3-TPN171 respectively. The method was validated for specificity, sensitivity, precision, accuracy, and other analytical parameters. The results found were satisfactory over the linear calibration range of 1-500 ng/mL. Within-day precisions ranged from 1.8 to 7.3 %, and between-day precisions from 2.3 to 4.9 %, accuracies were 95.5-99.8 %.The validated method was successfully applied to determine the plasma concentration after oral administration of 10 mg TPN171 in six healthy volunteers.

UI MeSH Term Description Entries
D011744 Pyrimidinones Heterocyclic compounds known as 2-pyrimidones (or 2-hydroxypyrimidines) and 4-pyrimidones (or 4-hydroxypyrimidines) with the general formula C4H4N2O. Pyrimidinone,Pyrimidone,Pyrimidones
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D002853 Chromatography, Liquid Chromatographic techniques in which the mobile phase is a liquid. Liquid Chromatography
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D053719 Tandem Mass Spectrometry A mass spectrometry technique using two (MS/MS) or more mass analyzers. With two in tandem, the precursor ions are mass-selected by a first mass analyzer, and focused into a collision region where they are then fragmented into product ions which are then characterized by a second mass analyzer. A variety of techniques are used to separate the compounds, ionize them, and introduce them to the first mass analyzer. For example, for in GC-MS/MS, GAS CHROMATOGRAPHY-MASS SPECTROMETRY is involved in separating relatively small compounds by GAS CHROMATOGRAPHY prior to injecting them into an ionization chamber for the mass selection. Mass Spectrometry-Mass Spectrometry,Mass Spectrometry Mass Spectrometry,Mass Spectrometry, Tandem
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
May 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
January 2014, Journal of pharmaceutical and biomedical analysis,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
October 2014, Biomedical chromatography : BMC,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
September 2014, Journal of pharmaceutical and biomedical analysis,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
June 2007, Biomedical chromatography : BMC,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
October 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
September 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
December 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
August 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Mengqi Zhang, and Haiming Liu, and Jiajin He, and Yuzhou Gui, and Hongjie Qian, and Jingying Jia, and Chen Yu, and Zhen Wang, and Jing Shan Shen, and Gangyi Liu
July 2012, Journal of pharmaceutical and biomedical analysis,
Copied contents to your clipboard!