A phantom study on dose efficiency for orthopedic applications: Comparing slot-scanning radiography using ultra-small-angle tomosynthesis to conventional radiography. 2021

Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Martensstr. 3, Erlangen, 91058, Germany.

OBJECTIVE This paper studies the abilities of a twin-robotic x-ray slot-scanning system for orthopedic imaging to reduce dose by scatter rejection compared to conventional digital radiography. METHODS We investigate the dose saving capabilities, especially in terms of the signal- and the contrast-to-noise ratio, as well as the scatter-to-primary ratio of the proposed slot-scanning method in comparison to the state-of-the-art method for length-extended imaging. As a baseline, we use x-ray parameters of two clinically established acquisition protocols that provide the same detector entrance dose but are profoundly different in patient dose. To obtain an estimate of the photon-related noise directly from an x-ray image, we implement a Poisson-Gaussian noise model. This model is used to compare the dose efficiency of two settings and combined with the well-known to determine the transmission parameters. We present a method with an associated measurement protocol, utilizing the robotic capabilities of the used system to automatically obtain quasi-scatter-free ground-truth data with exact geometric correspondence to full-field and slot acquisitions. In total, we investigate two body regions (thoracic spine and lumbar spine) in anterior-posterior view with two patient sizes (BMI = 22 and 30) in two acquisition modes (conventional and slot scan with a flat-panel detector) with and without anti-scatter grid using an anthropomorphic upper-body phantom. RESULTS We have shown that it is feasible to combine the proposed approach with the for the determination of scatter rejection parameters. The use of an anti-scatter grid is indicated for full-field acquisitions allowing for dose savings up to 46% compared to their gridless counterparts. When changing the acquisition mode to the investigated slot scan, the use of an anti-scatter grid has no major impact on the image quality in terms of dose efficiency, in particular for patients with a BMI of 22. However, an increased contrast improvement factor was found. For normal-sized patients, up to 53% of dose can be saved additionally in comparison to full-field acquisitions with grid. Moreover, we could demonstrate that a slot size of 5 cm and air gap of 10 cm is sufficient to achieve scatter-to-primary ratios, which are equal or better compared to those of the full-field acquisitions with a grid. CONCLUSIONS We have shown, that the slot-scanning approach is always superior to the conventional full-field acquisition in terms of signal-to-noise and scatter-to-primary ratios. Compared to the state-of-the-art acquisition protocols with a grid, dose savings up to 53% are possible due to the scatter rejection without compromising the SNR. Hence, the use of the slot-scanning method is indicated, especially when it comes to regularly carried-out follow-up acquisitions, for example, in the case of scoliosis monitoring.

UI MeSH Term Description Entries
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D011877 Radionuclide Imaging The production of an image obtained by cameras that detect the radioactive emissions of an injected radionuclide as it has distributed differentially throughout tissues in the body. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. Gamma Camera Imaging,Radioisotope Scanning,Scanning, Radioisotope,Scintigraphy,Scintiphotography,Imaging, Gamma Camera,Imaging, Radionuclide
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012542 Scattering, Radiation The diversion of RADIATION (thermal, electromagnetic, or nuclear) from its original path as a result of interactions or collisions with atoms, molecules, or larger particles in the atmosphere or other media. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Radiation Scattering,Radiation Scatterings,Scatterings, Radiation
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
January 2023, BMC medical imaging,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
June 2009, AJR. American journal of roentgenology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
April 2020, World journal of urology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
November 2014, Medical physics,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
January 2020, The Journal of urology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
December 2014, European radiology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
January 2013, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
January 2016, Journal of X-ray science and technology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
April 2019, Seminars in roentgenology,
Christoph Luckner, and Thomas Weber, and Magdalena Herbst, and Ludwig Ritschl, and Steffen Kappler, and Andreas Maier
July 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB),
Copied contents to your clipboard!