Long-term clinical results after mitral valve replacement with the Björk-Shiley prosthesis. 1988

D Lindblom
Department of Thoracic Surgery, Karolinska Hospital, Stockholm, Sweden.

The experience of 810 mitral valve replacements performed during a 15-year period (1969 to June 1983) is reported. All but one patient received a Björk-Shiley disc valve. Five different Björk-Shiley models were used (Delrin, n = 51; standard pyrolytic carbon, n = 307; convexo-concave with an opening angle of 60 degrees, n = 229; convexo-concave with an opening angle of 70 degrees, n = 123; and the Monostrut valve, n = 99). The follow-up was 99.8% complete and covered 4614 patient-years (mean 6.0 years). An autopsy was performed in 77% of all fatalities. Early mortality was 5.7% and decreased during the study period. The 5-, 10-, and 15-year actuarial survival rates (early mortality excluded) were 78%, 62%, and 51%, respectively, and the complication-free survival rates at the same time intervals were 67%, 51%, and 36%. Seven percent of early deaths and 25% of late deaths were valve related, and most of these were due to valve thrombosis. The incidence of valve thrombosis was significantly (p less than 0.0005) reduced after the introduction of the convexo-concave valves, and this reduction was achieved without any increase in bleeding complications. The only patient-related factor found to be related to postoperative thromboembolism was a history of preoperative embolism (p less than 0.05). Most events occurring after implant (death, embolism, valve thrombosis, reoperation, and valve failure) had a peak incidence during the first postoperative year, whereas anticoagulant-related bleedings occurred at a constant rate of 1.2/100 patient-years. The linearized incidence of embolism was 1.6/100 patient-years (actuarial incidence at 5 and 10 years 6.9% and 13.0%, respectively). Seven strut fractures occurred (0.2/100 patient-years, actuarial incidence at 5 and 10 years 1.1%), as did five instances of prosthetic valve endocarditis (0.1/100 patient-years, actuarial incidence at 5 and 10 years, 0.7% and 1.3%). A new concept of valve failure is presented and includes a distinction between events related to the surgical procedure (treatment failure; 1.9/100 patient-years, actuarial incidence at 5 and 10 years 11.0% and 13.5%) and events possibly related to the prosthesis (prosthetic failure; 1.1/100 patient-years, actuarial incidence at 5 and 10 years 7.0% and 8.0%).

UI MeSH Term Description Entries
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D011474 Prosthesis Design The plan and delineation of prostheses in general or a specific prosthesis. Design, Prosthesis,Designs, Prosthesis,Prosthesis Designs
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D003645 Death, Sudden The abrupt cessation of all vital bodily functions, manifested by the permanent loss of total cerebral, respiratory, and cardiovascular functions. Sudden Death
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

D Lindblom
January 1987, Scandinavian journal of thoracic and cardiovascular surgery,
D Lindblom
December 1971, The Journal of thoracic and cardiovascular surgery,
D Lindblom
January 1984, Archivos del Instituto de Cardiologia de Mexico,
D Lindblom
August 1979, The Thoracic and cardiovascular surgeon,
D Lindblom
January 1981, Scandinavian journal of thoracic and cardiovascular surgery,
D Lindblom
September 1996, Archives des maladies du coeur et des vaisseaux,
Copied contents to your clipboard!