Diagnostic Comparability and Interchangeability Between Daytime Ambulatory Blood Pressure Monitoring and 24-Hour Ambulatory Blood Pressure Monitoring in Detecting Masked Hypertension. 2020

Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
Cardiology, Ministry of National Guard - Health Affairs, King Saud Bin Abdulaziz University for Health Sciences, College of Medicine, Western Region (COM-WR) - King Abdullah International Medical Research Center, Jeddah, SAU.

Background The primary aim of this study was to evaluate the level of diagnostic overlap between daytime ambulatory blood pressure (BP) monitoring (DT-ABPM) and 24-hour ambulatory BP monitoring (24-h ABPM) in detecting masked hypertension (MH). Methods This is a prospective study that was performed in a sample of 196 soldiers aged between 21 and 50 years (without a history of hypertension) undergoing ABPM testing. The diagnosis of MH based on DT-ABPM defined as (office blood pressure (OBP) <140/90 and DT-ABPM ≥135/85) was compared with the 24-h ABPM defined as (OBP <140/90 mm Hg and 24-h ABPM ≥130/80 mm Hg). We critically analyzed the results to see the agreement between the two methods. Results The number of subjects classified as having MH based on both DT-ABPM and 24-h ABPM, only on 24-h ABPM, and only on DT-ABPM were 11 (5.6%), 29 (14.8%), and 18 (9.2%), respectively. The sensitivity, specificity, and positive and negative predictive values for DT-ABPM in detecting MH were: sensitivity = 100% (95% CI: 97.82% - 100%), specificity = 62.07% (95% CI: 42.26% - 79.31%), PPV = 93.82% (95% CI: 90.50% - 96.03%), and NPV = 100%, respectively. The level of agreement between DT-ABPM and 24-h ABPM in diagnosing MH was 94.4% and discordance in 5.6% (11/196); (kappa=0.736, p < 0.001). Conclusion The sensitivity, specificity, positive and negative predictive values all showed agreement between the two BP methods to confirm the diagnoses of MH. DT-ABPM can be used as an alternative to the 24-h ABPM. DT-ABPM eliminates sleep disturbance attributable to ABPM and maximizes patient compliance with the ABPM test. A further larger trial is needed for more confirmation and to affect the guidelines for using daytime ABPM.

UI MeSH Term Description Entries

Related Publications

Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
January 2018, The Canadian journal of cardiology,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
October 1988, American heart journal,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
February 2009, Praxis,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
May 2006, American heart journal,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
November 1998, Deutsche medizinische Wochenschrift (1946),
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
January 2001, The Journal of the American Board of Family Practice,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
December 1990, Deutsche medizinische Wochenschrift (1946),
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
January 2000, Vnitrni lekarstvi,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
February 1986, The American journal of cardiology,
Abdulhalim J Kinsara, and Ahmed Abuosa, and Alaa Meer, and Aymen H Elsheikh, and Mohammed Abrar, and Olga Vriz
November 2017, American journal of hypertension,
Copied contents to your clipboard!