Total hip acetabular component position affects component loosening rates. 1988

S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
Department of Orthopaedic Surgery, University of Iowa, Iowa City 52242.

Loosening is the most common long-term problem following total hip arthroplasty. Many factors, including patient selection, cement technique, femoral component placement, and prosthesis design reportedly affect the incidence of loosening. Theoretically, the location of the hip center of rotation substantially affects the load on the hip, and superior and lateral hip center location will result in higher loads than medial and inferior placement. Long-term follow-up studies (average, 9.1 years after surgery) using logistical regression analysis demonstrate significantly higher rates of femoral loosening with acetabular components placed in a superior and lateral (i.e., nonanatomic) position, compared with acetabular components placed in a nearly anatomic position.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D011859 Radiography Examination of any part of the body for diagnostic purposes by means of X-RAYS or GAMMA RAYS, recording the image on a sensitized surface (such as photographic film). Radiology, Diagnostic X-Ray,Roentgenography,X-Ray, Diagnostic,Diagnostic X-Ray,Diagnostic X-Ray Radiology,X-Ray Radiology, Diagnostic,Diagnostic X Ray,Diagnostic X Ray Radiology,Diagnostic X-Rays,Radiology, Diagnostic X Ray,X Ray Radiology, Diagnostic,X Ray, Diagnostic,X-Rays, Diagnostic
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005260 Female Females
D006621 Hip Joint The joint that is formed by the articulation of the head of FEMUR and the ACETABULUM of the PELVIS. Acetabulofemoral Joint,Acetabulofemoral Joints,Hip Joints,Joint, Acetabulofemoral,Joint, Hip,Joints, Acetabulofemoral,Joints, Hip
D006622 Hip Prosthesis Replacement for a hip joint. Femoral Head Prosthesis,Femoral Head Prostheses,Hip Prostheses,Prostheses, Femoral Head,Prostheses, Hip,Prosthesis, Femoral Head,Prosthesis, Hip
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000077 Acetabulum The part of the pelvis that comprises the pelvic socket where the head of FEMUR joins to form HIP JOINT (acetabulofemoral joint). Acetabula,Cotyloid Cavity,Acetabulas,Acetabulums,Cavities, Cotyloid,Cavity, Cotyloid,Cotyloid Cavities

Related Publications

S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
October 2013, The bone & joint journal,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
January 2017, The bone & joint journal,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
November 2012, The Orthopedic clinics of North America,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
January 2010, Hip international : the journal of clinical and experimental research on hip pathology and therapy,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
May 1984, Clinical orthopaedics and related research,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
January 1980, Acta orthopaedica Belgica,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
August 1983, Rontgen-Blatter; Zeitschrift fur Rontgen-Technik und medizinisch-wissenschaftliche Photographie,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
March 2013, ANZ journal of surgery,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
June 1979, Clinical orthopaedics and related research,
S A Yoder, and R A Brand, and D R Pedersen, and T W O'Gorman
August 2015, Medical engineering & physics,
Copied contents to your clipboard!