Intraoperative somatosensory evoked potential monitoring in scoliosis. 1988

E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
Department of Neurology, West Virginia University School of Medicine, Morgantown 26506.

During surgical correction of scoliosis, 63 patients had somatosensory evoked potential (SEP) monitoring of the spinal cord. Tibial nerves were unilaterally stimulated, and the potentials were recorded from the midcervical spine with surface and epidural needle electrodes. Over 85% had no significant change in their SEP and no postoperative neurologic deficits. Eleven percent had a significant change in their potential (amplitude decrease of greater than 60% and/or latency increase of greater than 2.5 msec) with no neurologic complications. One patient had a significant potential change and temporary postoperative sensory deficits did occur. One additional patient experienced postoperative neurologic complications but had no SEP change. This single false negative case, however, was clinically significant only for motor dysfunction, which is not monitored by the SEP. When changes in patient core temperature were compared to changes in SEP amplitude and latency, an intraoperative decrease in core temperature increased SEP latency and decreased amplitude, which may explain in part the false positive rate of the procedure.

UI MeSH Term Description Entries
D007430 Intraoperative Care Patient care procedures performed during the operation that are ancillary to the actual surgery. It includes monitoring, fluid therapy, medication, transfusion, anesthesia, radiography, and laboratory tests. Care, Intraoperative
D008297 Male Males
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D011930 Reaction Time The time from the onset of a stimulus until a response is observed. Response Latency,Response Speed,Response Time,Latency, Response,Reaction Times,Response Latencies,Response Times,Speed, Response,Speeds, Response
D001831 Body Temperature The measure of the level of heat of a human or animal. Organ Temperature,Body Temperatures,Organ Temperatures,Temperature, Body,Temperature, Organ,Temperatures, Body,Temperatures, Organ
D005073 Evoked Potentials, Somatosensory The electric response evoked in the CEREBRAL CORTEX by stimulation along AFFERENT PATHWAYS from PERIPHERAL NERVES to CEREBRUM. Somatosensory Evoked Potentials,Evoked Potential, Somatosensory,Somatosensory Evoked Potential
D005188 False Negative Reactions Negative test results in subjects who possess the attribute for which the test is conducted. The labeling of diseased persons as healthy when screening in the detection of disease. (Last, A Dictionary of Epidemiology, 2d ed) False Negative Reaction,Reaction, False Negative,Reactions, False Negative
D005189 False Positive Reactions Positive test results in subjects who do not possess the attribute for which the test is conducted. The labeling of healthy persons as diseased when screening in the detection of disease. (Last, A Dictionary of Epidemiology, 2d ed) False Positive Reaction,Positive Reaction, False,Positive Reactions, False,Reaction, False Positive,Reactions, False Positive
D005260 Female Females

Related Publications

E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
December 1986, Journal of neurosurgery,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
January 1995, Journal of pediatric orthopedics,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
January 1994, Journal of pediatric orthopedics,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
December 2004, Journal of spinal disorders & techniques,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
August 2009, Masui. The Japanese journal of anesthesiology,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
January 2019, Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
April 2012, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
August 2016, Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia,
E P Roy, and L Gutmann, and J E Riggs, and E T Jones, and J A Byrd, and R A Ringel
January 1992, Journal of orthopaedic trauma,
Copied contents to your clipboard!