The effects of three different contrast agents (Gd-BOPTA, Gd-DTPA, and Gd-DOTA) on brachial plexus magnetic resonance imaging. 2021

Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
Medical School of Chinese People's Liberation Army, Beijing, China.

BACKGROUND MRI is very important for guiding the diagnosis and treatment of brachial plexus diseases. The most used type of MRI brachial plexus imaging is the 3D Short Term Inversion Recovery (STIR) sequence with contrast agent. This study aimed to investigate the effect of three contrast agents; gadobenate dimeglumine (Gd-BOPTA), gadopentetate dimeglumine (Gd-DTPA), and Gadoteric Acid Meglumine (Gd-DOTA) on brachial plexus magnetic resonance imaging (MRI). METHODS We recruited 60 patients with suspected brachial plexus injury randomly into three groups. MRI images were obtained from each patient. Prior to scanning, the first group was injected with GD-BOPTA, the second group with Gd-DTPA, and the third with Gd-DOTA. The amount of contrast agent was 0.1 mmol/kg according to the weight of each patient, the injection rate was 1.5 mL/s, and 20 mL saline was injected at the same rate with a high-pressure injector. Immediately after the injection of contrast agent and saline, a 3D Sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE) STIR sequence was used for scanning. The Signal Intensity (SI) and Standard Deviation (SD) of Maximal intensity projection (MIP) images for regions outside the anatomy (ROI background) with area of 17 mm2 on both sides of the C6 peripheral nerves (ROI nerve), and tissue adjacent to the peripheral nerves (ROI tissue) were obtained. Signal to noise ratio (SNR) and contrast to noise ratio (CNR) were then calculated. RESULTS The SNR was 40.66±25.27, 34.65±14.86, and 44.63±30.79 for Gd-BOPTA, Gd-DTPA, and Gd-DOTA, respectively and the CNR was 20.24±15.17, 16.07±7.50, and 20.84±15.53 for Gd-BOPTA, Gd-DTPA, and Gd-DOTA, respectively. In addition, there was no statistical difference in the SNR or CNR of brachial plexus nerves using the three contrast agents to enhance the 3D SPACE sequence χ2=1.877, P=0.391>0.05 and χ2=1.717, P=0.424, respectively. CONCLUSIONS There were no significant differences in the efficacy of three contrast agents in imaging the brachial plexus.

UI MeSH Term Description Entries

Related Publications

Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
May 2007, Acta radiologica (Stockholm, Sweden : 1987),
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
July 2023, Journal of medicinal chemistry,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
November 1991, Investigative radiology,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
February 1996, Magnetic resonance imaging clinics of North America,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
May 1990, La Radiologia medica,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
December 2023, Biomacromolecules,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
February 2006, Zhonghua zhong liu za zhi [Chinese journal of oncology],
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
November 1991, Investigative radiology,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
January 2020, Current problems in diagnostic radiology,
Xiaojing Zhang, and Wensheng Wang, and Tiefang Liu, and Yeqing Qi, and Lin Ma
January 2006, Bioconjugate chemistry,
Copied contents to your clipboard!