Socket design and cement pressurisation in the Charnley low-friction arthroplasty. 1988

P Shelley, and B M Wroblewski
Centre for Hip Surgery, Wrightington Hospital, Wigan, Lancashire, England.

An experimental evaluation was made of the efficacy of an unflanged cup, an ogee-flanged cup and the Exeter pressuriser in the pressurisation of acetabular cement. Only a very modest injection pressure could be generated through an unflanged socket and even this was readily lost as the socket "bottomed out". The ogee-flanged socket gave a consistently high injection pressure which could be maintained throughout the process of polymerisation. The Exeter pressuriser gave marginally better results. Of the two cements tested, Palacos with gentamicin showed better intrusion than CMW Type 1 cement, but it also allowed greater extrusion once pressure was released. The importance of maintaining a continuous pressure on the cement throughout polymerisation is emphasised.

UI MeSH Term Description Entries
D011312 Pressure A type of stress exerted uniformly in all directions. Its measure is the force exerted per unit area. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Pressures
D011474 Prosthesis Design The plan and delineation of prostheses in general or a specific prosthesis. Design, Prosthesis,Designs, Prosthesis,Prosthesis Designs
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D001843 Bone Cements Adhesives used to fix prosthetic devices to bones and to cement bone to bone in difficult fractures. Synthetic resins are commonly used as cements. A mixture of monocalcium phosphate, monohydrate, alpha-tricalcium phosphate, and calcium carbonate with a sodium phosphate solution is also a useful bone paste. Bone Cement,Bone Glues,Bone Pastes,Bone Glue,Bone Paste,Cement, Bone,Cements, Bone,Glue, Bone,Glues, Bone,Paste, Bone,Pastes, Bone
D006621 Hip Joint The joint that is formed by the articulation of the head of FEMUR and the ACETABULUM of the PELVIS. Acetabulofemoral Joint,Acetabulofemoral Joints,Hip Joints,Joint, Acetabulofemoral,Joint, Hip,Joints, Acetabulofemoral,Joints, Hip
D006622 Hip Prosthesis Replacement for a hip joint. Femoral Head Prosthesis,Femoral Head Prostheses,Hip Prostheses,Prostheses, Femoral Head,Prostheses, Hip,Prosthesis, Femoral Head,Prosthesis, Hip
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

P Shelley, and B M Wroblewski
February 1995, The Journal of arthroplasty,
P Shelley, and B M Wroblewski
August 1994, The Journal of arthroplasty,
P Shelley, and B M Wroblewski
January 1978, Clinical orthopaedics and related research,
P Shelley, and B M Wroblewski
July 1988, The Orthopedic clinics of North America,
P Shelley, and B M Wroblewski
November 1985, The Journal of bone and joint surgery. British volume,
P Shelley, and B M Wroblewski
July 2006, Clinical orthopaedics and related research,
P Shelley, and B M Wroblewski
January 1993, Bulletin (Hospital for Joint Diseases (New York, N.Y.)),
P Shelley, and B M Wroblewski
June 1994, The Journal of arthroplasty,
P Shelley, and B M Wroblewski
February 1995, The Journal of arthroplasty,
Copied contents to your clipboard!