Smart automated heart health monitoring using photoplethysmography signal classification. 2021

Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
Department of Electronics and Communication Engineering, SRM Institute of Science and Technology, Kancheepuram, Tamil Nadu, India.

This paper proposes a smart, automated heart health-monitoring (SAHM) device using a single photoplethysmography (PPG) sensor that can monitor cardiac health. The SAHM uses an Orthogonal Matching Pursuit (OMP)-based classifier along with low-rank motion artifact removal as a pre-processing stage. Major contributions of the proposed SAHM device over existing state-of-the-art technologies include these factors: (i) the detection algorithm works with robust features extracted from a single PPG sensor; (ii) the motion compensation algorithm for the PPG signal can make the device wearable; and (iii) the real-time analysis of PPG input and sharing through the Internet. The proposed low-cost, compact and user-friendly PPG device can also be prototyped easily. The SAHM system was tested on three different datasets, and detailed performance analysis was carried out to show and prove the efficiency of the proposed algorithm.

UI MeSH Term Description Entries
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009038 Motion Physical motion, i.e., a change in position of a body or subject as a result of an external force. It is distinguished from MOVEMENT, a process resulting from biological activity. Motions
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D012815 Signal Processing, Computer-Assisted Computer-assisted processing of electric, ultrasonic, or electronic signals to interpret function and activity. Digital Signal Processing,Signal Interpretation, Computer-Assisted,Signal Processing, Digital,Computer-Assisted Signal Interpretation,Computer-Assisted Signal Interpretations,Computer-Assisted Signal Processing,Interpretation, Computer-Assisted Signal,Interpretations, Computer-Assisted Signal,Signal Interpretation, Computer Assisted,Signal Interpretations, Computer-Assisted,Signal Processing, Computer Assisted
D016477 Artifacts Any visible result of a procedure which is caused by the procedure itself and not by the entity being analyzed. Common examples include histological structures introduced by tissue processing, radiographic images of structures that are not naturally present in living tissue, and products of chemical reactions that occur during analysis. Artefacts,Artefact,Artifact
D017156 Photoplethysmography Plethysmographic determination in which the intensity of light reflected from the skin surface and the red cells below is measured to determine the blood volume of the respective area. There are two types, transmission and reflectance. Light Reflection Rheography,Photoreflexometry,Rheography, Light Reflection,Light Reflection Rheographies,Photoplethysmographies,Photoreflexometries,Rheographies, Light Reflection
D020407 Internet A loose confederation of computer communication networks around the world. The networks that make up the Internet are connected through several backbone networks. The Internet grew out of the US Government ARPAnet project and was designed to facilitate information exchange. World Wide Web,Cyber Space,Cyberspace,Web, World Wide,Wide Web, World

Related Publications

Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
November 2013, IEEE transactions on systems, man, and cybernetics. Systems,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
April 2015, Epilepsy & behavior : E&B,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
February 2018, JMIR cardio,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
January 2020, Journal of electrocardiology,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
January 2013, PloS one,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
December 2023, Physical and engineering sciences in medicine,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
February 2017, Sensors (Basel, Switzerland),
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
August 2013, Journal of biomedical optics,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
February 2024, Scientific reports,
Remya Raj, and Jayakumar Selvakumar, and Vivek Maik
July 2022, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation,
Copied contents to your clipboard!