[Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. 1988

G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
Servizio di Poligrafia, Ospedale S. Camillo, Roma.

The study was performed to assess Doppler echocardiographic features of mitral and aortic prosthetic valves of different types with both normal and abnormal function. Two hundred and twenty-three patients with 250 prostheses were studied. Two hundred eight valves (111 mitral, 95 aortic and 2 tricuspid) were considered to be functioning normally after clinical examination, phonocardiography and M-mode and 2D echocardiography. This group enabled us to define normal Doppler echocardiographic findings for different types of prosthesis. In mitral position, peak (p) and mean (m) gradients were lower for disc prostheses and higher for ball and biological prosthetic valves; values of effective orifice area (A), calculated by pressure half-time method, were lower for biological and ball prostheses and higher in disc valves. Results were as follows: St. Jude (p 10.6 mmHg, m 3.9 mmHg, A 2.7 cm2), Duromedics (p 10.6, m 4.3, A 2.8), Björk-Shiley (p 10.4, m 4, A 2.3), Omniscience (p 14.2, m 6.2, A 2.1), Starr-Edwards (p 15.9, m 5.4, A 2.1), Hancock (p 14.7, m 6, A 2), Carpentier (p 13.2, m 5.4, A 1.9). Mild regurgitation, considered "physiological", was found in 2/8 Carpentier valves and in 3/34 St. Jude prostheses. In aortic valves lower peak gradients were found in Lillehei (18.3 mmHg), St. Jude (23.8 mmHg), Björk-Shiley (26 mmHg), Duromedics (27 mmHg) and higher values in Starr-Edwards (30.2 mmHg), Hancock (30 mmHg) and Omniscience (35.5 mmHg) prostheses. Mild regurgitation, considered "physiological", was found in 17% of Omniscience valves, 21% of Hancock, 33% of Duromedics, 45% of St. Jude, 60% of Björk-Shiley prostheses. Hancock mitral valves implanted for over 7 years had a mean gradient higher than valves with a shorter period of implantation (7.6 vs 4.85 mmHg, p less than 0.1), whereas the effective orifice area was similar. Hancock aortic valves implanted for over 7 years had a peak gradient slightly higher than the other group (implantation less than 7 years previously), but the difference was not statistically significant. Forty-two valves (19 aortic and 23 mitral) were considered to be malfunctioning. Regurgitation Doppler signals of malfunctioning valves appeared different from those of "physiological" reverse flow; in the former cases forward gradient was higher than normal prostheses. In stenotic aortic prostheses, peak systolic gradient was greatly increased; in stenotic mitral prostheses, a very significant increase in mean gradient and a great decrease in effective orifice area were found. In 14 patients who underwent surgical re-operation and in the patient who died before operation, Doppler echocardiographic findings were confirmed.(ABSTRACT TRUNCATED AT 400 WORDS)

UI MeSH Term Description Entries
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001021 Aortic Valve The valve between the left ventricle and the ascending aorta which prevents backflow into the left ventricle. Aortic Valves,Valve, Aortic,Valves, Aortic
D001705 Bioprosthesis Prosthesis, usually heart valve, composed of biological material and whose durability depends upon the stability of the material after pretreatment, rather than regeneration by host cell ingrowth. Durability is achieved 1, mechanically by the interposition of a cloth, usually polytetrafluoroethylene, between the host and the graft, and 2, chemically by stabilization of the tissue by intermolecular linking, usually with glutaraldehyde, after removal of antigenic components, or the use of reconstituted and restructured biopolymers. Glutaraldehyde-Stabilized Grafts,Heterograft Bioprosthesis,Porcine Xenograft Bioprosthesis,Xenograft Bioprosthesis,Bioprostheses,Bioprostheses, Heterograft,Bioprostheses, Porcine Xenograft,Bioprostheses, Xenograft,Bioprosthesis, Heterograft,Bioprosthesis, Porcine Xenograft,Bioprosthesis, Xenograft,Glutaraldehyde Stabilized Grafts,Glutaraldehyde-Stabilized Graft,Graft, Glutaraldehyde-Stabilized,Grafts, Glutaraldehyde-Stabilized,Heterograft Bioprostheses,Porcine Xenograft Bioprostheses,Xenograft Bioprostheses,Xenograft Bioprostheses, Porcine,Xenograft Bioprosthesis, Porcine
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D014261 Tricuspid Valve The valve consisting of three cusps situated between the right atrium and right ventricle of the heart. Tricuspid Valves,Valve, Tricuspid,Valves, Tricuspid

Related Publications

G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
April 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
January 1984, Kardiologia polska,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
May 1990, Zeitschrift fur die gesamte innere Medizin und ihre Grenzgebiete,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
September 1994, New Jersey medicine : the journal of the Medical Society of New Jersey,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
December 1995, The American journal of cardiology,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
September 1993, Minerva cardioangiologica,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
November 1992, Zeitschrift fur Kardiologie,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
October 1991, Nederlands tijdschrift voor geneeskunde,
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
January 1987, Revmatologiia (Moscow, Russia),
G Minardi, and M Di Segni, and L Boccardi, and O Ferrari, and E Giovannini
May 1997, Zeitschrift fur Kardiologie,
Copied contents to your clipboard!