Reduction of body doses in rotational panoramic radiography by means of reduced beam width in combination with rare earth intensifying screens. 1986

A Aagaard, and I Sewerin

The absorbed doses in the body of a Rando-Alderson phantom were measured in rotational panoramic radiography (OP-5) with LiF-700 crystals using conventional intensifying screens and standard collimator, as well as rare earth intensifying screens and a collimator slit of reduced width. The reduction of the absorbed doses obtained by using the latter combination was calculated. The reduction range in different regions was 0-50%. The greatest reduction was obtained in the cranial part of the phantom. In the caudal part little or no reduction was observed, probably because leakage radiation contributes substantially to the absorbed doses in this area. The average dose equivalent was calculated for organs in which measurements were made in several locations. The reduction was about 50% for these organs except for the gonads (8%). Compared to the estimated average annual dose equivalent originating from the natural background radiation sources, the dose equivalent resulting from this X-ray examination was very small except in the thyroid gland. In this organ the dose equivalent from one exposure corresponded to 36 days of natural background radiation, but it could be reduced to 18 days by using rare earth intensifying screens in combination with reduced beam width.

UI MeSH Term Description Entries
D008348 Manikins Inanimate physical models which bear likeness to human beings and are used for various purposes in place of humans. Mannequins,Manikin,Mannequin
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D011862 Radiography, Panoramic Extraoral body-section radiography depicting an entire maxilla, or both maxilla and mandible, on a single film. Orthopantomography,Panoramic Radiography,Pantomography,Orthopantomographies,Panoramic Radiographies,Pantomographies,Radiographies, Panoramic
D013819 Thermoluminescent Dosimetry The use of a device composed of thermoluminescent material for measuring exposure to IONIZING RADIATION. The thermoluminescent material emits light when heated. The amount of light emitted is proportional to the amount of ionizing radiation to which the material has been exposed. Dosimetries, Thermoluminescent,Dosimetry, Thermoluminescent,Thermoluminescent Dosimetries
D014963 X-Ray Intensifying Screens Screens which absorb the energy in the x-ray beam that has penetrated the patient and convert this energy into a light pattern which has as nearly as possible the same information as the original x-ray beam. The more light a screen produces for a given input of x-radiation, the less x-ray exposure and thus shorter exposure time are needed to expose the film. In most film-screen systems, the film is sandwiched between two screens in a cassette so that the emulsion on each side is exposed to the light from its contiguous screen. Film-Screen Systems, X-Ray,Radiographic Intensifying Screens,Screen-Film Systems, X-Ray,X-Ray Film-Screen Systems,Screens, Radiographic Intensifying,Xray Intensifying Screens,Film Screen Systems, X Ray,Film-Screen System, X-Ray,Intensifying Screen, Radiographic,Intensifying Screen, X-Ray,Intensifying Screen, Xray,Intensifying Screens, Radiographic,Intensifying Screens, X-Ray,Intensifying Screens, Xray,Radiographic Intensifying Screen,Screen Film Systems, X Ray,Screen, Radiographic Intensifying,Screen, X-Ray Intensifying,Screen, Xray Intensifying,Screen-Film System, X-Ray,Screens, X-Ray Intensifying,Screens, Xray Intensifying,System, X-Ray Film-Screen,System, X-Ray Screen-Film,Systems, X-Ray Film-Screen,Systems, X-Ray Screen-Film,X Ray Film Screen Systems,X Ray Intensifying Screens,X-Ray Film-Screen System,X-Ray Intensifying Screen,X-Ray Screen-Film System,X-Ray Screen-Film Systems,Xray Intensifying Screen

Related Publications

A Aagaard, and I Sewerin
April 1984, Oral surgery, oral medicine, and oral pathology,
A Aagaard, and I Sewerin
January 1990, The Angle orthodontist,
A Aagaard, and I Sewerin
January 1976, Radiography,
A Aagaard, and I Sewerin
November 1975, Radiography,
A Aagaard, and I Sewerin
November 1978, The Journal of small animal practice,
A Aagaard, and I Sewerin
October 1984, Tandlaegebladet,
A Aagaard, and I Sewerin
April 1978, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
Copied contents to your clipboard!