Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey. 2022

T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka.

The main purpose of this study was to establish for the first time national diagnostic reference levels (NDRLs) for common computed tomography (CT) procedures in Sri Lanka. Patient morphometric data, exposure parameters and dose data such as volume CT dose index (CTDIvol) and dose-length product (DLP) were collected from 5666 patients who underwent 22 types of procedure. The extreme dose values were filtered before analysis to ensure that the data come from standard size patients. The median of the dose distribution was calculated for each institution, and the third quartile value of the median distribution was considered as the NDRL. Based on the inclusion and exclusion criteria, data from 4592 patients and 17 procedure types were considered for establishment of a NDRL, covering 41% of the country's CT machines. The proposed NDRLs based on CTDIvoland DLP were: non-contrast-enhanced (NC) head, 82.2 mGy/1556 mGy cm; contrast-enhanced (CE) head, 82.2 mGy/1546 mGy cm; chest NC, 7.4 mGy/350 mGy cm; chest CE, 8.3 mGy/464 mGy cm; abdomen NC, 10.5 mGy/721 mGy cm; abdomen arterial (A) phase, 13.4 mGy/398 mGy cm; abdomen venous (V) phase, 10.8 mGy/460 mGy cm; abdomen delay (D) phase, 12.6 mGy/487 mGy cm; sinus NC, 30.2 mGy/452 mGy cm; lumbar spine NC, 24.1 mGy/1123 mGy cm; neck NC, 27.5 mGy/670 mGy cm; high-resolution CT of chest, 10.3 mGy/341 mGy cm; kidneys ureters and bladder NC, 19.4 mGy/929 mGy cm; chest to pelvis (CAP) NC, 10.8 mGy/801 mGy cm; CAP A, 10.4 mGy/384 mGy cm; CAP V, 10.5 mGy/534 mGy cm; CAP D, 16.8 mGy/652 mGy cm. Although the proposed NDRLs are comparable with those of other countries, the observed broad dose distributions between the CT machines within Sri Lanka indicate that dose optimisation strategies for the country should be implemented for most of the CT facilities.

UI MeSH Term Description Entries
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000082162 Diagnostic Reference Levels Radiological values used as guides to indicate whether the radiation dosage or amount of radiopharmaceutical being given to a patient is unusually high or unusually low for the specific medical imaging procedure. Diagnostic Reference Level,Reference Level, Diagnostic,Reference Levels, Diagnostic
D013188 Sri Lanka Country in southern Asia, an island in the Indian Ocean, south of India. The capital is Colombo. Ceylon
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
June 2020, European journal of radiology,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
June 2018, Journal of radiological protection : official journal of the Society for Radiological Protection,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
November 2023, Radiation protection dosimetry,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
February 2023, Acta radiologica (Stockholm, Sweden : 1987),
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
January 2014, Journal of medical physics,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
November 2020, Radiation protection dosimetry,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
June 2020, Radiation protection dosimetry,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
January 2010, Radiation protection dosimetry,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
October 2020, European radiology,
T Amalaraj, and Duminda Satharasinghe, and Aruna Pallewatte, and Jeyasingam Jeyasugiththan
February 2021, Journal of radiological protection : official journal of the Society for Radiological Protection,
Copied contents to your clipboard!