Fluorescent anti-immunoglobulin G assay of circulating immune complexes extracted with polyethylene glycol. 1986

S S Levinson, and J Goldman

After a polyethylene glycol extraction which removes monomeric immunoglobulin G (IgG), circulating immune complexes were assayed by the FIAX fluorescence assay (Whittaker M. A. Bioproducts, Walkersville, Md.). The extraction portion of the procedure can be completed within a few hours after an overnight precipitation step, and the fluorescence assay takes about 0.5 h. The fluorescence assay is similar to the routine FIAX method for measuring IgG in cerebrospinal fluid except that a 10-microliter sample from sera is substituted for a 50-microliter sample. Good parallelism between endogenous immune complexes, monomeric IgG, and aggregated human globulin, along with good between-run precision (coefficients of variation, less than 10%), indicates that monomeric IgG calibrators from the kit could be used to standardize the assay. This standardization eliminates the need for aggregated human globulin, which is unstable and difficult to prepare. A reference range of 9 to 63 mg/liter followed a gaussian distribution. Correlation data indicate that the test provides information similar to the C1q-binding test (rho = 0.87; n = 30) but has better diagnostic sensitivity and better discrimination in the high range. Because of its simplicity, good reproducibility, and accessibility to equipment available in many laboratories, the method described here may be a preferred technique for measuring circulating immune complexes.

UI MeSH Term Description Entries
D007074 Immunoglobulin G The major immunoglobulin isotype class in normal human serum. There are several isotype subclasses of IgG, for example, IgG1, IgG2A, and IgG2B. Gamma Globulin, 7S,IgG,IgG Antibody,Allerglobuline,IgG(T),IgG1,IgG2,IgG2A,IgG2B,IgG3,IgG4,Immunoglobulin GT,Polyglobin,7S Gamma Globulin,Antibody, IgG,GT, Immunoglobulin
D011092 Polyethylene Glycols Polymers of ETHYLENE OXIDE and water, and their ethers. They vary in consistency from liquid to solid depending on the molecular weight indicated by a number following the name. They are used as SURFACTANTS, dispersing agents, solvents, ointment and suppository bases, vehicles, and tablet excipients. Some specific groups are NONOXYNOLS, OCTOXYNOLS, and POLOXAMERS. Macrogols,Polyoxyethylenes,Carbowax,Macrogol,Polyethylene Glycol,Polyethylene Oxide,Polyethyleneoxide,Polyglycol,Glycol, Polyethylene,Glycols, Polyethylene,Oxide, Polyethylene,Oxides, Polyethylene,Polyethylene Oxides,Polyethyleneoxides,Polyglycols,Polyoxyethylene
D003166 Complement Activating Enzymes Enzymes that activate one or more COMPLEMENT PROTEINS in the complement system leading to the formation of the COMPLEMENT MEMBRANE ATTACK COMPLEX, an important response in host defense. They are enzymes in the various COMPLEMENT ACTIVATION pathways. Activating Enzymes, Complement,Enzymes, Complement Activating
D005455 Fluorescent Antibody Technique Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy. Antinuclear Antibody Test, Fluorescent,Coon's Technique,Fluorescent Antinuclear Antibody Test,Fluorescent Protein Tracing,Immunofluorescence Technique,Coon's Technic,Fluorescent Antibody Technic,Immunofluorescence,Immunofluorescence Technic,Antibody Technic, Fluorescent,Antibody Technics, Fluorescent,Antibody Technique, Fluorescent,Antibody Techniques, Fluorescent,Coon Technic,Coon Technique,Coons Technic,Coons Technique,Fluorescent Antibody Technics,Fluorescent Antibody Techniques,Fluorescent Protein Tracings,Immunofluorescence Technics,Immunofluorescence Techniques,Protein Tracing, Fluorescent,Protein Tracings, Fluorescent,Technic, Coon's,Technic, Fluorescent Antibody,Technic, Immunofluorescence,Technics, Fluorescent Antibody,Technics, Immunofluorescence,Technique, Coon's,Technique, Fluorescent Antibody,Technique, Immunofluorescence,Techniques, Fluorescent Antibody,Techniques, Immunofluorescence,Tracing, Fluorescent Protein,Tracings, Fluorescent Protein
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000936 Antigen-Antibody Complex The complex formed by the binding of antigen and antibody molecules. The deposition of large antigen-antibody complexes leading to tissue damage causes IMMUNE COMPLEX DISEASES. Immune Complex,Antigen-Antibody Complexes,Immune Complexes,Antigen Antibody Complex,Antigen Antibody Complexes,Complex, Antigen-Antibody,Complex, Immune,Complexes, Antigen-Antibody,Complexes, Immune
D015922 Complement C1q A subcomponent of complement C1, composed of six copies of three polypeptide chains (A, B, and C), each encoded by a separate gene (C1QA; C1QB; C1QC). This complex is arranged in nine subunits (six disulfide-linked dimers of A and B, and three disulfide-linked homodimers of C). C1q has binding sites for antibodies (the heavy chain of IMMUNOGLOBULIN G or IMMUNOGLOBULIN M). The interaction of C1q and immunoglobulin activates the two proenzymes COMPLEMENT C1R and COMPLEMENT C1S, thus initiating the cascade of COMPLEMENT ACTIVATION via the CLASSICAL COMPLEMENT PATHWAY. C1q Complement,Complement 1q,Complement Component 1q,C1q, Complement,Complement, C1q,Component 1q, Complement

Related Publications

S S Levinson, and J Goldman
January 1979, Journal of immunological methods,
S S Levinson, and J Goldman
December 1990, Journal of immunological methods,
S S Levinson, and J Goldman
November 1979, Clinical and experimental immunology,
S S Levinson, and J Goldman
December 1981, American journal of clinical pathology,
S S Levinson, and J Goldman
January 1981, Journal of immunological methods,
S S Levinson, and J Goldman
June 1984, Journal of clinical & laboratory immunology,
Copied contents to your clipboard!