Solid-phase immunoassay of digoxin by measuring time-resolved fluorescence. 1986

P Helsingius, and I Hemmilä, and T Lövgren

We describe a time-resolved fluoroimmunoassay for the cardiac glycoside digoxin. The assay depends on the competitive distribution of Eu3+-labeled anti-digoxin antibodies between solid-phase-bound digoxin and the digoxin in the sample or standard. After this immunoreaction, the bound fraction of the Eu3+-label is dissociated from the solid phase, converted into a highly fluorescent beta-diketone chelate, and measured in a fluorometer with time-resolution (1230 Arcus, LKB-Wallac). Sample volume is 20 microL, the incubation lasts 30 min, and the concentration range of the assay for digoxin is from 0.25 to 4.0 ng/mL (0.32-5.1 nmol of digoxin per liter). Correlation with an in-house RIA was good (r = 0.97, n = 43). The sensitivity was equivalent to that of most RIAs: 0.2 ng/mL (0.25 nmol/L).

UI MeSH Term Description Entries
D007553 Isotope Labeling Techniques for labeling a substance with a stable or radioactive isotope. It is not used for articles involving labeled substances unless the methods of labeling are substantively discussed. Tracers that may be labeled include chemical substances, cells, or microorganisms. Isotope Labeling, Stable,Isotope-Coded Affinity Tagging,Isotopically-Coded Affinity Tagging,Affinity Tagging, Isotope-Coded,Affinity Tagging, Isotopically-Coded,Isotope Coded Affinity Tagging,Labeling, Isotope,Labeling, Stable Isotope,Stable Isotope Labeling,Tagging, Isotope-Coded Affinity,Tagging, Isotopically-Coded Affinity
D011933 Reagent Kits, Diagnostic Commercially prepared reagent sets, with accessory devices, containing all of the major components and literature necessary to perform one or more designated diagnostic tests or procedures. They may be for laboratory or personal use. Diagnostic Reagent Kits,Diagnostic Reagents and Test Kits,Diagnostic Test Kits,In Vitro Diagnostic Device,In Vitro Diagnostic Devices,In Vitro Diagnostic Medical Device,In Vitro Diagnostic Medical Devices,Kits, Diagnostic Reagent,Diagnostic Reagent Kit,Diagnostic Test Kit,Kit, Diagnostic Reagent,Kit, Diagnostic Test,Kits, Diagnostic Test,Reagent Kit, Diagnostic,Test Kit, Diagnostic,Test Kits, Diagnostic
D003429 Cross Reactions Serological reactions in which an antiserum against one antigen reacts with a non-identical but closely related antigen. Cross Reaction,Reaction, Cross,Reactions, Cross
D004077 Digoxin A cardiotonic glycoside obtained mainly from Digitalis lanata; it consists of three sugars and the aglycone DIGOXIGENIN. Digoxin has positive inotropic and negative chronotropic activity. It is used to control ventricular rate in ATRIAL FIBRILLATION and in the management of congestive heart failure with atrial fibrillation. Its use in congestive heart failure and sinus rhythm is less certain. The margin between toxic and therapeutic doses is small. (From Martindale, The Extra Pharmacopoeia, 30th ed, p666) Digacin,Digitek,Digoregen,Digoxina Boehringer,Digoxine Nativelle,Dilanacin,Hemigoxine Nativelle,Lanacordin,Lanicor,Lanoxicaps,Lanoxin,Lanoxin-PG,Lenoxin,Mapluxin,Boehringer, Digoxina,Lanoxin PG,Nativelle, Digoxine,Nativelle, Hemigoxine
D005063 Europium An element of the rare earth family of metals. It has the atomic symbol Eu, atomic number 63, and atomic weight 152. Europium is used in the form of its salts as coatings for cathode ray tubes and in the form of its organic derivatives as shift reagents in NMR spectroscopy.
D005455 Fluorescent Antibody Technique Test for tissue antigen using either a direct method, by conjugation of antibody with fluorescent dye (FLUORESCENT ANTIBODY TECHNIQUE, DIRECT) or an indirect method, by formation of antigen-antibody complex which is then labeled with fluorescein-conjugated anti-immunoglobulin antibody (FLUORESCENT ANTIBODY TECHNIQUE, INDIRECT). The tissue is then examined by fluorescence microscopy. Antinuclear Antibody Test, Fluorescent,Coon's Technique,Fluorescent Antinuclear Antibody Test,Fluorescent Protein Tracing,Immunofluorescence Technique,Coon's Technic,Fluorescent Antibody Technic,Immunofluorescence,Immunofluorescence Technic,Antibody Technic, Fluorescent,Antibody Technics, Fluorescent,Antibody Technique, Fluorescent,Antibody Techniques, Fluorescent,Coon Technic,Coon Technique,Coons Technic,Coons Technique,Fluorescent Antibody Technics,Fluorescent Antibody Techniques,Fluorescent Protein Tracings,Immunofluorescence Technics,Immunofluorescence Techniques,Protein Tracing, Fluorescent,Protein Tracings, Fluorescent,Technic, Coon's,Technic, Fluorescent Antibody,Technic, Immunofluorescence,Technics, Fluorescent Antibody,Technics, Immunofluorescence,Technique, Coon's,Technique, Fluorescent Antibody,Technique, Immunofluorescence,Techniques, Fluorescent Antibody,Techniques, Immunofluorescence,Tracing, Fluorescent Protein,Tracings, Fluorescent Protein
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000906 Antibodies Immunoglobulin molecules having a specific amino acid sequence by virtue of which they interact only with the ANTIGEN (or a very similar shape) that induced their synthesis in cells of the lymphoid series (especially PLASMA CELLS).
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

P Helsingius, and I Hemmilä, and T Lövgren
December 2004, Guang pu xue yu guang pu fen xi = Guang pu,
P Helsingius, and I Hemmilä, and T Lövgren
July 1984, FEBS letters,
P Helsingius, and I Hemmilä, and T Lövgren
January 1986, Clinical chemistry,
P Helsingius, and I Hemmilä, and T Lövgren
January 1985, Talanta,
P Helsingius, and I Hemmilä, and T Lövgren
January 1990, Voprosy meditsinskoi khimii,
P Helsingius, and I Hemmilä, and T Lövgren
May 2011, Scandinavian journal of clinical and laboratory investigation,
P Helsingius, and I Hemmilä, and T Lövgren
August 1989, Journal of pharmaceutical sciences,
P Helsingius, and I Hemmilä, and T Lövgren
March 1990, Clinical chemistry,
P Helsingius, and I Hemmilä, and T Lövgren
March 1997, Journal of immunological methods,
P Helsingius, and I Hemmilä, and T Lövgren
February 1992, Analytical chemistry,
Copied contents to your clipboard!